HOME STANDBY GENERATOR- ALL aXis CONTROLLER
Transfer Power Direction
Shows the direction of power
House
Icon for house receiving power
HSB
The HSB icon will indicate power when the generator is the source
of power
aXis CONTROLLER INfORMATION ICONS
The information icons are located at the bottom right side of aXis
Controller icon touch pad.
Hour Meter
MODELS
®
The hour meter keeps track of all running time of the HSB. This
includes run time during a utility power outage and during the
weekly exercise cycle. This provides the owner with a record
of operating time which is useful in keeping track of scheduled
maintenance intervals. Refer to the scheduled maintenance chart.
The hour meter can't be reset. The initial time registered on the
meter when first started up (installed) will reflect the factory test
time, this is a normal industry standard. The hour meter only
reflects hours, it does not reflect RPMs or any other function.
Exercise Icon
The BLUE icons will be lit when the HSB is performing the exercise
period. Refer to "Setting Exercise Time" to establish the weekly
exercise period. When the exercise period is complete the icon will
turn off and the HSB will resume its standby monitoring.
aXis CONTROLLER fAULT ICONS
Low Oil Pressure Shutdown
The RED icon will be lit when the engine oil pressure drops below
a safe operating level. When this fault is detected, the HSB will
shut down and re-start will be disabled. RED icon on the controller
module and exterior LED will be lit.
Check the oil level. The oil level should be at the FULL mark, if
necessary, add oil. DO NOT overfill. Inspect the unit for a possible
oil leak, if a leak is discovered, contact Champion or your nearest
Authorized Champion Dealer. Follow the FAULT CODE RESET
instructions to clear the fault after service.