Descargar Imprimir esta página

STAMOS S-LS-118 Manual De Instrucciones página 31

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 123
Note:
Set the slope and current value to be range dependent. The maximum slope of the small range is
0.24A/μS, the maximum current can be set to 3A, the maximum slope of the large range is 3.2A/ μS, and
the maximum current can be set to 40A.
The maximum frequency can be set to 40,000Hz. When the frequency is set to 40,000Hz, the maximum
duty cycle is 50%.
Refer to Section "Load maximum setting" for the current maximum setting.
3.3.2.
Dynamic CV
Used for output with different duty cycles at two different voltages at a certain frequency.
Take the A voltage of 1V, the B voltage of 2V, the cycle frequency of 1 HZ, and the duty cycle of 40% as an
example.
Operations:
1) Press (F1) DYN/CALL, TAB to select DYN/CALL, and turn the knob to CV.
2) Press (F2) DYN/SAVE to display SAVE on the screen.
3) Press TAB to switch the focus and turn the knob to select the first row.
4) Press ENTER to select the red background.
5) Enter numeric 0 to 9, and ESC.
6) After editing as 1.0001, press ENTER. Then 1.0000 will be displayed on the screen, and the background
will be switched to blue.
7) Repeat the above steps to set 2V, 1 HZ, and 40% respectively.
8) Long press ENTER to save the edited data.
9) Press (F1) DYN/CALL to display CALL.
10) Press ENTER to call DYN CV.
11) Turn ON/OFF.
3.3.3.
Dynamic CW
The operation is the same as above.
3.3.4.
Dynamic CR
The operation is the same as above.
3.3.5.
Dynamic PL
It is set to the value A at the beginning. Each time a trigger signal is received, the load is switched to the
value B, and switched to the value A aga in after the set time is maintained.
Fig. 3.1 DYN CC

Publicidad