3.10.5.
Setting of remote compensation
Press TAB to switch to Remote Comp, select ON, and connect the output end of the object to be tested to
the terminal sense(+) or sense(-) on the front panel (this function is not saved during the blackout,
otherwise it is closed).
3.10.6.
Setting of external triggering
Press TAB to switch to EXI P TRIG and turn the knob to select Trig On/Switch On/OFF.
Trig On: triggering switch (open load after triggering)
Switch on: remote switch (ON/OFF function on the front panel will not work when this function works).
3.10.7.
Setting of maximum values
1) Maximum voltage
Press TAB to switch to Voltage. ESC is the delete key, and numeric 0 to 9 is for entering numbers. The
maximum voltage is 150V.
2) Maximum current
Press TAB to switch to Current. ESC is the delete key, and numeric 0 to 9 is for entering numbers. The
maximum current is 40A.
3) Maximum power
Press TAB to switch to Power. ESC is the delete key, and numeric 0 to 9 is for entering numbers. The
maximum power depends on the model.
4) Maximum resistance
Press TAB to switch to Resistance. ESC is the delete key, and numeric 0 to 9 is for entering numbers. The
maximum resistance is 7500R.
Note: 18V and below is set to be the low voltage range (0 to 18V), and above
18. 4V is set to be the high voltage range (0 to 150V).
3A and below is set to be the low current range (0 to 3A), and above 3. 1A is set to be the high current
range (O to 40A).
OVP alarm value: it is (19. 4V) at the low range and (155V) at the high range. OCP alarm value: it is 105% of
the set current value. For example, if the current is set to be SA, the alarm value is 5.25A.
OPP alarm value: it is 105% of the set power value. For example, if the power value is set to be 100W, the
alarm value is 105W.
OTP alarm value: if the temperature is higher than 85,an alarm will begiven, and the load will be closed.
3.10.8.
RTC setting
Long press numeric 7, and then date will be displayed on the screen as shown in Fig. 10.2.
Press ← or → to move the focus and turn the knob to make modification. After modification, long press
ENTER or numeric 7 to save, and press ESC to exit.
3.10.9.
Backlight setting
After long pressing numeric 8, the progress bar will be displayed on the screen as shown in Fig. 10.3.
Fig. 10.2 RTC Date