The following takes the current slope A of 0.001 A/ μS, the current slope B of 0.002 A/uS, the current value
A of 1 A, the current value B of 2A, and the duration B of 1s as an example.
Operations:
1) Press (F1) DYN/CALL, press TAB to select CALLYN, and turn the knob to PL.
2) Press (F2) DYN/SAVE to display SAVE on the screen.
3) Press TAB to switch the focus and turn the knob to select the first row.
4) Press ENTER to select the red background.
5) Enter numeric 0 to 9, and ESC.
6) After editing as 0.001, press ENTER. Then 0.0010 will be displayed on the screen, and the background
will be switched to blue.
7) Repeat the above steps to set 0.002A/uS, 1A, 2A, and 1a respectively.
8) Long press ENTER to save the edited data.
9) Press the soft key (F1) DYN/CALL to display CALL.
10) Press ENTER to call DYN RL.
11) Turn ON/OFF.
12) Trigger the value B every time you press ENTER.
3.3.6.
Dynamic RL
Each time a trigger signal is received, the load is switched back and forth between the value A and the
value B.
Take the current slope A of 0.001 A/μS, the current slope B of 0.002A/μS, the current value A of 1A, and
the current value B of 2A as an example. Operations:
1) Press (F1) DYN/CALL, press TAB to select DYN/CALL, and turn the knob to RL.
2) Press (F2) DYN/SAVE to display SAVE on the screen.
3) Press TAB to switch the focus and turn the knob to select the first row.
4) Press ENTER to select the red background.
5) Enter numeric 0 to 9, and ESC.
6) After editing as 0.001, press ENTER. The n 0.0010 will be displayed on the screen, and the background
will be switched to blue.
7) Repeat the above steps to set 0.002A/μS, 1A, and 2A respectively.
8) Long press ENTER to save the edited data.
9) Press the soft key (F1) DYN/CALL to display CALL.
10) Press ENTER to call DYN RL.
11) Turn ON/OFF.
12) Trigger the value B every time you press ENTER.
3.4.
Sequential Operation Mode
A maximum of 7 groups can be stored, each group can set up to 84 dynamically changing currents, and
then the set currents can be switched in sequence. Take the settings stored in Group 1, the maximum
current of 3A, and the number of the dynamic change current of 3;, the first dynamic current of 1A, the
change rate of 0.001 A/uS, and the duration of 1s; the second dynamic current of 2A, the change rate of
0.002A/uS, and the duration of 2s; the third dynamic current of 3A, the change rate of 0.003A/μS, and the
duration of 3s; the number of repeated operations of 5 as an example. As shown in Fig. 4.1 List.
Operations:
1) Press (F3) LIST/CALL press TAB to select GROUP, and turn the knob to Group 1.
2) Press (F4) LIST/SAVE to display SAVE on LIST.
3) Press TAB to switch the focus, select RANGE and edit the maximum value of 3A via numeric 0 to 9 and
ESC.
4) Press TAB to select CYCLE. The number of editing cycles is 5.
5) Press TAB to the first row of LIST and press ENTER. At this time, the background turns red.
Edit the first item DATA value of 1A. After editing, press ENTER, and the background will be switched to
blue.