1) After the USB flash disk is inserted, USB key is displayed on home page. Press (F4) USB.
2) Press TAB to switch to SAVE, turn the knob to select BAT mode, press ← or → to select Group, and
turn the knob to Group 1.
3) After pressing {FS) SAVE CSV, a message will prompt that it has been exported. Import DYN_PL_Set.csv
from USB flash disk to DYN PL.
4) Press TAB to switch to LOAD, adjust to DYN mode and turn the knob to PL.
5) List a tree of fil es on the left and turn the knob to select the file DYN_PL Set.CSV to be imported.
6) After pressing (F4) LOAD CSV, successful import will be prompted.
3.11.2.
U Flash Disk Storage of Real-time Data of Load Test
If the real-time test data is saved with a U flash disk, the data volume is to save the voltage and current
data 5 times per second.
The operation procedures are as follows:
1) Press F6 (Config), use Tab to switch the focus on USB Stare (Fig. 10.1 Parameter Setting).
Use ESC to delete, enter the number key 0.2, which means to save 5 times per second.
2) There are 2 ways to open the save data file.
<1> Turn on or off data saving in the menu interface: enter the U flash disk page (Fig. 11.1 Storage
Interface of USB Flash Disk). Press (F1) "Start Save Data" to start, then the top status bar will have a down
arrow flashing, indicating that the data is being saved right now.
To stop writing, re-enter the USB flash disk page, the n press (F2) "Stop Save Data". And the top arrow will
disappear.
<2> Shortcut key to open or close the operation: in the state of inserting the U flash disk, long press the
number key 9 to start the U flash disk saving, and long press the number key 9 again to stop saving.
Refer to Fig. 11.4 Data Write Icon
3.12.
Cleaning and maintenance
a)
Always unplug the device before cleaning or putting it away.
b)
Use only non-corrosive cleaners to clean the surface.
c)
After cleaning the device, all parts should be dried completely before using it again.
d)
Store the unit in a dry, cool place, free from moisture and direct exposure to sunlight.
e)
Do not spray the device with a water jet or submerge it in water.
f)
Do not allow water to get inside the device through vents in the housing of the device.
g)
Clean the vents with a brush and compressed air.
h)
The device must be regularly inspected to check its technical efficiency and spot any damage.