7.13 Installing a communication interface module
WARNING
Electric shock
Death or serious personal injury
Switch off the power supply to the
product including the power supply for
the signal relays. Wait at least 5
minutes before you make any
connections in the terminal box. Make
sure that the power supply cannot be
switched on accidentally.
8. Starting up the product
WARNING
Rotating parts
Death or serious personal injury
Make sure to install the coupling
guards before powering on the
product.
WARNING
Corrosive liquids
Death or serious personal injury
Wear personal protective equipment.
14
RJ45
NO
DI3
24V
5V
A
Y
AI2
5V
TX
RX
OFF
ON
B
AI1
DI1
24V
AO1
WARNING
Toxic liquids
Death or serious personal injury
Wear personal protective equipment.
CAUTION
Cold surface
Minor or moderate personal injury
Make sure that no one can accidentally
come into contact with cold surfaces.
Wear protective gloves.
CAUTION
Hot surface
Minor or moderate personal injury
Do not touch the product while it is
running.
Follow the startup instructions for the
pump. See the related installation and
operating instructions for the pump.
S24
ST1 ST2
DI4
PT2 PT1 LT1
LT2