differences in color. In this way, correct use enables surfaces and objects to be subjected to non-contacting
examination for temperature differences or anomalies to render components and/or weaknesses, if present,
visible, including:
thermal envelopes and insulation (e.g. to identify thermal bridges)
active heating-water and hot-water lines (e.g. underfloor heating) in floor and walls
overheated electrical components (e.g. fuses or terminals in switchgear cabinets)
faulty or damaged parts of machinery (e.g. overheating due to faulty ball bearings)
The measuring tool is suitable for use indoors and outdoors. USA/Canada: Use the measuring tool only
indoors.
For this product, use only Hilti lithium­ion batteries of the B 12 series. For this product, Hilti recommends
the use of the batteries stated in this table.
For these batteries, use only Hilti chargers of the type series stated in this table.
3.4
Restrictions on use and misuse
The measuring tool is not suitable for the temperature measurement of gases.
Do not use the measuring tool for human-medicine or veterinary-medicine purposes.
3.5
Items supplied
Thermal imaging camera, USB cable, button-cell battery (in the product), operating instructions
Other system products approved for use with this product can be found at your local Hilti Store or at:
www.hilti.group
3.6
Charge status display
The charge status of the Li­ion battery is displayed after pressing the release button.
Status
4 LEDs show.
3 LEDs show.
2 LEDs show.
1 LED shows.
1 LED flashes.
Battery charge status cannot be displayed while the control switch is pressed.
4
Technical data
4.1
Technical data
Resolution, infrared sensor
Thermal sensitivity (Mean value in accordance with the VDI 5585
standard)
Spectral range
Field of view (FOV) (in accordance with the VDI 5585 standard)
Focus distance (in accordance with the VDI 5585 standard)
Focus
Refresh rate, thermal image
Measured area, surface temperature (in accordance with the
VDI 5585 standard)
30
English
Meaning
Charge status: 75 % to 100 %
Charge status: 50 % to 75 %
Charge status: 25 % to 50 %
Charge status: 10 % to 25 %
Charge status: < 10 %
256 x 192 px
≤ 0.05 K
8 µm ... 14 µm
40° x 30°
≥ 0.3 m
fixed
9 Hz
−20 ℃ ... 600 ℃