2. With the measuring tool switched off, use the USB cable to establish the connection between the USB
port on the tool and your PC.
Use the USB interface only for connecting the measuring tool to a PC. Attempts to connect to
other devices can damage the measuring tool.
3. Switch the measuring tool on. → page 33
4. Open the file browser on your PC and select "PTC" as the drive. The files saved in the measuring tool's
internal memory can be copied, moved to your PC, or deleted.
5. As soon as you have completed the desired procedure, disconnect the drive in the standard way.
Invariably, you first have to log out the drive from your PC's operating system (Eject drive), as
otherwise the measuring tool's internal memory can be damaged.
6. Then switch the measuring tool off at the on/off switch.
7. Disconnect the USB cable and close the cover over the USB port to protect against dirt and spray.
8
Care and maintenance
WARNING
Risk of injury with battery inserted !
▶ Always remove the battery before carrying out care and maintenance tasks!
Care of the product
•
Carefully remove stubborn dirt.
•
Carefully clean the air vents, if present, with a dry, soft brush.
•
Use only a slightly damp cloth to clean the housing. Do not use cleaning agents containing silicone as
these can attack the plastic parts.
•
Use a dry, clean cloth to clean the contacts of the product.
•
Keep the measuring tool clean at all times. A dirty infrared sensor can impair measuring accuracy.
•
Do not use pointed objects to attempt to remove dirt from the infrared sensor, camera, speaker or
microphone. Blow dust off the infrared sensor and camera. Do not wipe the infrared sensor and camera
(risk of scratching).
Care of the Liion batteries
•
Never use a battery with clogged air vents. Clean the air vents carefully using a dry, soft brush.
•
Avoid unnecessary exposure of the battery to dust and dirt. Never expose the battery to high levels of
moisture (e.g. by being dipped in water or left in the rain).
If a battery has been soaked by moisture, treat it as a damaged battery. Isolate it in a non-flammable
container and consult Hilti Service.
•
Keep the battery free of extraneous oil and grease. Do not permit dust or dirt to accumulate unnecessarily
on the battery. Clean the battery with a dry, soft brush or a clean, dry cloth. Do not use cleaning agents
containing silicone as these can attack the plastic parts.
Do not touch the contacts of the battery and do not remove the factory-applied grease from the contacts.
•
Use only a slightly damp cloth to clean the housing. Do not use cleaning agents containing silicone as
these can attack the plastic parts.
Maintenance
WARNING
Danger of electric shock! Improper repairs to electrical components may lead to serious injuries including
burns.
▶ Repairs to the electrical section of the tool or appliance may be carried out only by trained electrical
specialists.
•
Check all visible parts and controls for signs of damage at regular intervals and make sure that they all
function correctly.
•
Do not use the product if signs of damage are found or if parts malfunction. Immediately have the product
repaired by Hilti Service.
•
After cleaning and maintenance, install all guards and protective devices and check that they are in full
working order.
40
English
2356162