The entry and exit of conductors to the terminal box will be done using cable glangs
that guarantee tightness and the absence of humidity and dirt. The conductors will have
appropriate terminals fos appropiate fixing.
START UP
6.4 Pump priming
Before starting up, the pump must be primed with water. The water cools and
lubricates the mechanical seal.
With the pump working on load, it is not necessary to prime it. The pump Works on
load if the pool water leve lis above the pump axis. However it is recommended that due
to pressure losses and flow valves, that there is at least 1.5m height available from the
pump axis to the pool water level.
With the pump in suction, you must remove the side drain plug from the pump to
proceed to fill it until making sure that the entire suction circuit is full of water as shown in
the drawing. You can also prime the pump through the prefilter, if the pump has one.