Descargar Imprimir esta página

Garant GMT35 Manual De Uso página 27

Maquina de rectificado deslizante
Ocultar thumbs Ver también para GMT35:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 157
Fault
Pump fails to start.
11. Technical data
External dimensions of the machine
(Length × Width x Height)
Internal dimensions of the trough
(Length × Width x Height)
Total volume of the trough
Nett filling capacity of the trough
Wear coating (PU) of the trough
Speed of the vibratory motor
Water tank capacity
Water pump throughput
Control panel
Machine weight
Vibratory unit weight
Control voltage
Operating voltage
Current drawn by the vibratory motor
Power of the vibratory motor
Total power
Main supply fuse
12. Disposal
Comply with the national and regional environmental protection
and disposal regulations for correct disposal or recycling. Segreg-
ate items into metals, non-metals, composite materials and con-
sumables and dispose of them responsibly. Re-use is preferable to
disposal.
13. Original EU/CE declaration of conformity
NAME AND ADDRESS OF THE MANUFACTURER
Hoffmann Supply Chain GmbH • Poststraße 15 • 90471 Nuremberg • Germany
WE DECLARE UNDER OUR SOLE RESPONSIBILITY THAT THE
PRODUCTS MENTIONED
Brand
GARANT
Article number
501300, 501305
Size
GMT35
Model
GMT35
Type
Serial number (range)
General designation
GMT35 mass finishing machine
Trade name
Function description
The mass finishing system together with
abrasive beads or polishing beads and an
additive is used for surface processing of
components
satisfy all applicable provisions of the following European harmonisation regu-
lations
Applied EU/EC directives
2006/42/EG, 2014/53/EU, 2011/65/EU
and comply with the following standards.
Applied standards
EN ISO 12100:2010, EN 60204-1:2018, EN
IEC 63000:2018
Applied technical standards and specifications
IEC 62321-1:2013
NAME AND ADDRESS OF PERSON AUTHORISED TO COMPILE THE
TECHNICAL DOCUMENTS
Hoffmann Engineering Services GmbH • Haberlandstr. 55 • 81241 Munich • Germany
Possible cause
No power supply to the pump.
1550 mm × 710 mm × 1390 mm
590 mm × 180 mm × 300 mm
35 litres
30 litres
15 mm
1,500 - 3,000 rpm
45 litres
25 litres per hour
PLC-based 1×230 V, 50 – 60 Hz, single
phase
360 kg
138 kg
24 V-DC
230 V, 50 Hz, single phase
2.8 A
0.68 kW
0.70 kW
10 A
Action
Check the supply cables.
Munich, 01.01.2021
Alexander Eckert,
Managing Director
Performed by
Trained specialist for electro-technical work.
www.hoffmann-group.com