YASKAWA TOMPYEULA7002A LA700 Series Installation and Operation Instruction
Table 1.5 Keypad Components and Functions
• Illuminates to show that the drive is operating the motor.
• The LED turns OFF when the drive stops.
• Flashes to show that:
– The drive is decelerating to stop.
– The drive received an Up/Down command with a speed reference of 0 Hz, but the drive is not set for zero speed control.
• Flashes quickly to show that:
– The drive received an Up/Down command from the MFDI terminals and is switching to REMOTE Mode while the drive is in
LOCAL Mode.
– The drive received an Up/Down command from the MFDI terminals when the drive is not in Drive Mode.
– The drive received an Emergency Stop command.
– The safety function shut off the drive output.
– You pushed
on the keypad while the drive is operating in REMOTE Mode.
• Illuminates when the drive detects a fault.
• Flashes when the drive detects:
– Alarm
– Operation Errors
– A fault or alarm during Auto-Tuning
• The light turns off during regular drive operation. There are no alarms or faults.
The insertion point for a microSD card.
The menu shown on the keypad sets the functions for function keys.
The name of each function is in the lower half of the display window.
Illuminated: The keypad controls the Up/Down command (LOCAL Mode).
OFF: The control circuit terminal or serial transmission device controls the Up/Down command (REMOTE Mode).
Note:
• LOCAL: Use the keypad to operate the drive. Use the keypad to enter Up/Down and Stop commands and the speed reference
command.
• REMOTE: Use the control circuit terminals or serial transmission to operate the drive. Use the speed reference source entered in
b1-01 [Speed Reference Selection 1] and the Up/Down command source selected in b1-02 [Up/Down Command Selection 1].
Switches drive control for the Up/Down command and speed reference between the keypad (LOCAL) and an external source
(REMOTE).
Note:
• The LOCAL/REMOTE Selection Key continuously stays enabled after the drive stops in Drive Mode. If the application must not
switch from REMOTE to LOCAL because it will have a negative effect on system performance, set o2-01 = 0 [LO/RE Key
Function Selection = Disabled] to disable
• The drive will not switch between LOCAL and REMOTE when it is receiving an Up/Down command from an external source.
Stops drive operation.
Note:
Push
to stop the motor. This will also apply when an Up/Down command (REMOTE Mode) is active at an external Up/
Down command source. To disable
• Moves the cursor to the left.
• Goes back to the previous screen.
• Scrolls up or down to show the next item or the previous item.
• Selects parameter numbers, and increments or decrements setting values.
• Moves the cursor to the right.
• Continues to the next screen.
• Resets the drive to clear a fault.
• Enters parameter values and settings.
• Selects menu items to move between keypad displays.
• Selects each mode, parameter, and set value.
Starts the drive in LOCAL Mode.
Starts the operation in Auto-Tuning Mode.
Note:
Before you use the keypad to operate the motor, push
For factory adjustment
Connects to the drive using an RJ-45 8-pin straight through UTP CAT5e extension cable or keypad connector.
Function
.
priority, set o2-02 = 0 [STOP Key Function Selection = Disabled].
on the keypad to set the drive to LOCAL Mode.
1 English