Connecting The Irob Robot Welding Power Source En - Abicor Binzel iROB P400 Instructivo De Servicio

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

iROB
6.4 Connecting the
iROB robot welding power source
NOTICE
• Please observe the operating instructions of the welding components, coolant recirculator iCOOL
1
13
12
11
10
1
Gas connection
2
CAN bus
3
Control lead connecting socket
for intermediate cable assembly
Fig. 6
Connection of the intermediate cable assembly
1 Insert the control lead (12) into the control lead connecting socket for the intermediate cable
assembly (3) and fasten it by turning the nut clockwise.
2 Insert power cable (11) into positive connecting socket for the welding current (5) and tighten it by
turning it clockwise.
3 Connect gas hose (13) to gas connection (1) (pressure reducing valve) of the gas cylinder or to the gas
supply line.
4 Connect the coolant supply and return hoses (9), (10) to the connections (6), (7). For liquid-cooled
systems only.
5 Connect the ground cable (8) to the negative connecting socket for the welding current (4).
(option), wire feeder iFEED (option), remote control iCONTROL (option) and welding torch.
9
4
Negative connecting socket for welding current
5
Positive connecting socket for welding current
6
Coolant supply connection
7
Coolant return connection
8
7
8
Ground cable
9
Coolant supply hose
10 Coolant return hose
11 Welding power cable
6 Putting into operation
2
3
4
5
6
12 Control lead
13 Gas hose
EN - 15