10.1
Acquisition procedure WITH the encoder enabled, WITH or WITHOUT
electric limit switches
TEST
CLOSED
PROG
PROG
AP P-
x4 s
1 click
AU to
1
... wait...
MOTOR 2
CLOSING
• Press and hold PROG for 4 seconds,
• Press PROG again.
• MOTOR 1 starts opening at normal speed.
• After the delay time set with parameter
• Once the gate open mechanical stop is reached or the relative limit switch is activated, the gate stops briefly. The message
flashes on the display for 2 s.
• When the message
set with parameter
(default setting 5 s), MOTOR 1 closes until the gate closed mechanical stop or the relative limit
switch is reached.
If the acquisition procedure is completed successfully, the display enters the command and safety device state display mode.
If the following error messages are shown on the display, repeat the acquisition procedure:
: acquisition error. Press the TEST button to clear the error, and check the safety device in alarm state.
For more information, see chapter 15 "Alarms and faults".
58
TEST
41
No
1 click
Yes
TEST
1 click
00
AU to
1
MOTOR 1
OPENING
PARAM. 26
DELAY
2
TIME
... wait...
is shown on the display.
is shown on the display.
, (with a default time setting of 3 s) MOTOR 2 starts an opening manoeuvre.
stops flashing and is steadily lit on the display, MOTOR 2 closes first and then, after a delay
A
See chapter 14 and 15
PARAM. 25
DELAY
1
TIME
... wait...
MOTOR 2
OPENING
2
1
MOTOR 1
GATE
CLOSING
CLOSED
AU to
2
GATE
OPEN
Yes
x2 s

Publicidad