Configuring sensing edge COS1
Sensing edge NOT INSTALLED.
NC contact (normally closed). The gate reverses only when opening.
Contact with 8k2 resistor. The gate reverses only when opening.
NC contact (normally closed). The gate always reverses.
Contact with 8k2 resistor. The gate always reverses.
Configuring sensing edge COS2
Sensing edge NOT INSTALLED.
NC contact (normally closed). The gate reverses only when closing.
Contact with 8k2 resistor. The gate reverses only when closing.
NC contact (normally closed). The gate always reverses.
Contact with 8k2 resistor. The gate always reverses.
Configure encoder
N.B.: if no encoder is installed, time based control is used.
if this parameter is modified, disconnect from 230 V AC mains power, wait for the display to turn off then
reconnect to mains power. Repeat acquisition procedure, see Chapter 10.
No encoder installed.
Optical encoders installed (8 pulses/revolution).
E30 Series. Magnetic encoders installed (1 pulse/revolution)
R21 series (version V.1). Magnetic encoders installed (1 pulse/revolution).
Configuring radio channel 1 (PR1)
Configuring radio channel 2 (PR2)
STEP MODE.
PARTIAL OPENING
OPENING
CLOSING.
STOP.
Courtesy light. The output COR is managed from the remote control. The light remains lit as long as the
remote control is active. The parameter
Courtesy light ON-OFF (PP). The output COR is managed from the remote control.
The remote control turns the courtesy light on and off. The parameter
FLASHING LIGHT. The FLASHING LIGHT output is managed from the remote control. The light remains lit as
long as the remote control is active. The parameter
FLASHING LIGHT ON-OFF. The FLASHING LIGHT output is managed from the remote control.
The remote control turns the courtesy light on and off. The parameter
Configuring flashing light frequency
The frequency is set electronically from the flashing light unit.
Slow flash.
Light flashes slowly when gate opens, rapidly when gate closes.
Selecting courtesy light mode
Disabled.
PULSE. The courtesy light illuminates briefly at the start of each manoeuvre.
ACTIVE. The light remains lit for the entire duration of the manoeuvre.
From 3 to 90 s. The light remains lit for the time period set after the manoeuvre is completed.
From 2 to 9 minutes. The light remains lit for the time period set after the manoeuvre is completed.
70
is ignored.
is ignored.
is ignored.
is ignored.