Commands and Accessories

If not installed, safety devices with NC contacts must be jumpered at the COM terminals, or disabled by modifying the
parameters
,
,
KEY:
N.A. (Normally Open).
N.C. (Normally Closed).
CONTACT
10(COR)
11
12(LAM)
13
14
15(ANT)
16 17
19
16
18 19
20(FCA1)
24(COM)
21(FCC1)
24(COM)
22(FCA2)
24(COM)
23(FCC2)
24(COM)
26(ORO)
25(COM)
27(AP)
31(COM)
28(CH)
31(COM)
52
,
,
and
.
DESCRIPTION
Output (potential free contact) for connecting courtesy light. 230 Vac 100 W (fig. 6).
Connection for flashing light (potential free contact) 230 Vac 40 W (fig. 6).
The settings for the pre-manoeuvre flashing warning signal may be selected with parameter
, while the flashing mode is set with parameter
Antenna connector for slot-in radio receiver board.
Use RG58 if an external antenna is used; maximum recommended length: 10 m.
N.B.: do not make joints in cable.
MOTOR 1 ENCODER connection (fig. 7-8-9).
Encoders are disabled by default (
WARNING! Always disconnect from electrical power before disconnecting or connecting
the encoder cable.
MOTOR 2 ENCODER connection (fig. 7-8-9).
Encoders are disabled by default (
WARNING! Always disconnect from electrical power before disconnecting or connecting
the encoder cable.
Input (N.C.) for connecting open limit switch for MOTOR 1 (fig. 6-7).
Use a 4x0.5 mm
2
cable to connect the limit switch to the control unit.
The gate stops when the limit switch is activated.
When the gate is completely open, the control unit display shows
Input (N.C.) for connecting closed limit switch for MOTOR 1 (fig. 6-7).
2
Use a 4x0.5 mm
cable to connect the limit switch to the control unit.
The gate stops when the limit switch is activated.
When the gate is completely closed, the control unit display shows
Input (N.C.) for connecting open limit switch for MOTOR 2 (fig. 6-7).
2
Use a 4x0.5 mm
cable to connect the limit switch to the control unit.
The gate stops when the limit switch is activated.
When the gate is completely open, the control unit display shows
Input (N.C.) for connecting closed limit switch for MOTOR 2 (fig. 6-7).
Use a 4x0.5 mm
2
cable to connect the limit switch to the control unit.
The gate stops when the limit switch is activated.
When the gate is completely closed, the control unit display shows
Clock timer contact input (N.O.).
When the clock function is active, the gate opens and remains open.
At the end of the programmed time set with the external device (clock), the gate closes.
The function of this command is determined by parameter
Open control signal input (N.O.).
Close command input (N.O.).
.
).
).
.
.
.
.
.