Parameter menu
PARAMETER
PARAMETER
Motor type selection
Speed motor (4-pole)
Slow motor (6-pole) - (R20/302, R20/502, R21/368, H23/282, R41/832, R41/833)
Automatic closure after pause time (from gate completely open)
Disabled.
From 1 to 15 of gate closure attempts after photocell is triggered.
Once the number of attempts set is reached, the gate remains open.
The gate tries to close indefinitely.
Automatic gate closing after mains power outage
Disabled. The gate does not close automatically when mains power is restored.
Enabled. If the gate is NOT completely open, when mains power is restored, the gate closes after a 5 second
warning signalled with the flashing light (independently of the value set with the parameter
closes in "position recovery" mode (see chapter 17).
Selecting step mode control function (PP)
Open-stop-close-stop-open-stop-close...
Condominium function: the gate opens and closes after the set automatic closing time.
The automatic closing timer restarts if a new step mode command is received.
Step mode commands are ignored while the gate is opening. This allows the gate to open completely and
prevents the gate from closing when not required.
If automatic closing is disabled (
noeuvre
Condominium function: the gate opens and closes after the set automatic closing time.
The automatic closing timer does NOT restart if a new step mode command is received.
Step mode commands are ignored while the gate is opening. This allows the gate to open completely and
prevents the gate from closing when not required.
If automatic closing is disabled (
noeuvre
Open-close-open-close.
Open-close-stop-open.
Pre-flashing
Disabled. The flashing light is activated during opening and closing manoeuvres.
Flashing warning signal for 1 to 10 seconds prior to every manoeuvre.
5 second flashing warning signal prior to closing manoeuvre.
Condominium function for partial open command (PED)
Disabled. The gate opens partially in step mode: open-stop-close-stop-open...
Enabled. Partial commands are ignored during gate opening.
64
VALUE
), the condominium function automatically attempts a closing ma-
.
), the condominium function automatically attempts a closing ma-
.
). The gate