Set initial acceleration when opening/closing (soft-start)
Disabled.
Enabled. The gate accelerates slowly and progressively at the start of the manoeuvre.
Enabled. The gate accelerates even more slowly and progressively at the start of the manoeuvre.
N.B.: values available only if encoder is enabled (
mended for heavy gates.
Set motor torque after activation of sensing edge or encoder.
Disabled. Torque applied is the value set for parameter
1 = minimum motor torque ... 8 = maximum motor torque.
Enable maximum torque boost at start of manoeuvre
If this parameter is enabled, each time the motor starts the maximum boost torque is applied for a settable
period of time to allow the gate to start moving.
From 0 to 20 s.
Set open/closed stop approach distance
Disabled.
= 0.5 m long gate leaf;
gate leaf ≥ 2.5 m in length.
If this function is enabled, the torque applied is reduced during the final part of the gate travel to reduce gate
vibration when it reaches the stop.
On installations with an electric lock, the torque applied is increased during the final part of the closing travel to
ensure that the lock latches correctly. On installations with no electric lock, the torque applied is reduced during the
final part of the gate travel to reduce gate vibration.
N.B.: parameter visible only if encoder is enabled
Enable electric lock release reverse impulse
Disabled.
Enabled. At the start of each opening manoeuvre, the control unit applies a brief closing force (settable from 1
to 4 s) to release the electric lock.
Enabling the electric lock release reverse impulse function automatically enables parameters
lock lead time = 1 s) and
Set deceleration during opening/closure
Disabled.
Medium deceleration.
N.B.: maximum settable value for 6 pole motors (R20/302, R20/502, R21/368, H23/282, R41/832,
R41/833)..
Maximum deceleration. IMPORTANT: Use ONLY in oustanding possibilities, for example gates very light. DO
NOT USE 6 pole motors (R20/302, R20/502, R21/368, H23/282, R41/832, R41/833).
Set obstacle detection sensitivity during manoeuvres
The gate reverses immediately when an obstacle is detected during an opening or closing manoeuvre.
NOTE: The maximum value is limited to
Set obstacle detection sensitivity during deceleration
The gate reverses immediately when an obstacle is detected during opening or closing deceleration.
NOTE: The maximum value is limited to
From 1% to 99%.
= minimum sensitivity ...
different from
.
= 1 m long gate leaf;
= 1.5 m long gate leaf;
.
(electric lock activation time = 3 s).
for 6-pole slow motors (
for 6-pole slow motors (
= maximum sensitivity.
). Setting a value of
is not recom-
= 2 m long gate leaf;
).
).
=
(electric