Enabling operator present function.
Disabled.
Enabled. The open (AP) or close (CH) button must be pressed continuously to operate the gate. The gate stops
when the button is released.
Gate open indicator / photocell test function
The indicator is off when the gate is closed, and steadily lit during manoeuvres and when the gate is open.
The indicator flashes slowly during opening manoeuvres, and is lit steadily when the gate is completely open.
It flashes quickly during closing manoeuvres.
If the gate is stopped in an intermediate position, the lamp extinguishes twice every 15 seconds.
Set
if the output SC is used for the photocell test. See fig. 5.
Set MOTOR 1 deceleration space (%)
N.B.: if no encoder is installed, repeat the travel acquisition procedure after any change made to this parameter.
Set MOTOR 2 deceleration space (%)
N.B.: if no encoder is installed, repeat the travel acquisition procedure after any change made to this parameter.
From 1% to 30% of the total gate travel.
LEAF 1 completely open/closed position control adjustment
N.B.: parameter visible only with encoder enabled (
(
or
).
If
, the factory value becomes
The selected value must ensure that LEAF 1 is opened/closed correctly when it reaches the respective (open
or closed) mechanical stop.
The position of LEAF 1 is calculated by the system from the number of motor revolutions and the motor
reduction gear ratio.
Warning! Excessively low values cause the gate to reverse when it reaches the gate open/closed stop.
LEAF 2 completely open/closed position control adjustment
N.B.: parameter visible only with encoder enabled (
(
or
).
If
, the factory value becomes
The selected value must ensure that LEAF 2 is opened/closed correctly when it reaches the respective (open
or closed) mechanical stop.
The position of LEAF 2 is calculated by the system from the number of motor revolutions and the motor
reduction gear ratio.
Warning! Excessively low values cause the gate to reverse when it reaches the gate open/closed stop.
Motor revolutions.
Partial opening adjustment (%)
N.B.: with double leaf swing gate installations, this parameter is set by default as the completely open position
of LEAF 1.
With single leaf swing gate installations, this parameter is set to 50% of total opening.
From 1% to 99% of total gate travel.
Setting additional time after direction inversion, with no encoder
N.B.: parameter visible only if encoder is disabled
In the event of photocell activation or a reverse command during an opening or closing manoeuvre, the gate
reverses for the elapsed manoeuvre time plus an additional time to allow the manoeuvre to be completed.
3 s.
6 s. Recommended setting for installations with hydraulic motors.
Setting automatic closing time
The timer starts from the gate open state and continues for the set time. Once the set time is reached, the
gate closes automatically. The timer count restarts if a photocell is triggered.
Pause time settable from 00 to 90 s.
Pause time settable from 2 to 9 min.
or
.
or
.
.
) and if limit switches are not installed
) and if limit switches are not installed