Parameter
PID error
PID feed-back
PID offs. Sel
Offest 0
Offset 1
PID offset 0
PID offset 1
PID acc time [s]
PID dec time [s]
PID clamp
PI P gain PID %
PI I gain PID %
PI steady thr
PI steady delay [ms]
P init gain PID %
I init gain PID %
PI central v sel
PI central v1
PI central v2
PI central v3
PI top lim
PI bottom lim
PI integr freeze
OFF
PI output PID
Real FF PID
PD P gain 1 PID [%]
PD D gain 1 PID [%]
PD P gain 2 PID [%]
PD D gain 2 PID [%]
PD P gain 3 PID [%]
PD D gain 3 PID[%]
PD D filter PID [ms]
PD output PID
PID out sign PID
Positive
Bipolar
PID output
PID target
PID out scale
Diameter calc
Enabled
Disabled
Positioning spd [rpm]
Max deviation
Gear box ratio
Dancer constant [mm]
Minimum diameter [cm]
PI central vs0
PI central vs1
Diameter calc st
Cap.3
290
No Format
min
OPTIONS \ PID \ PID references
759
I16
-10000
763
I16
-10000
762
U16
0
760
I16
-10000
761
I16
-10000
1046
Float
0.0
1047
Float
0.0
757
I16
0
OPTIONS \ PID \ PI controls
765
Float
0.00
764
Float
0.00
695
I16
0
731
U16
0
793
Float
0.00
734
Float
0.00
779
U16
0
776
Float
P785
777
Float
P785
778
Float
P785
784
Float
P785
785
Float
-10.00
783
U16
0
ON
771
I16
0
418
I16
-10000
OPTIONS \ PID \ PD controls
768
Float
0.00
766
Float
0.00
788
Float
0.00
789
Float
0.00
790
Float
0.00
791
Float
0.00
767
U16
0
421
I16
-10000
772
U16
0
774
I16
-10000
OPTIONS \ PID \ PID target
782
U16
0
773
Float
-100.000
OPTIONS \ PID \ Diameter calc
794
U16
0
795
I16
-100
796
I16
-10000
797
Float
0.001
798
U16
1
799
U16
1
780
U16
0
781
U16
0
800
U16
0
——— Lista de parámetros ———
SIEI
Value
max
Factory
10000
0
10000
0
1
Offset 0 (0)
10000
0
10000
0
900.0
0.0
900.0
0.0
10000
10000
100.00
10.00
100.00
10.00
10000
0
60000
0
100.00
10.00
100.00
10.00
3
1
P784
1.00
P784
1.00
P784
1.00
10.00
10.00
P784
0
1
0
OPTIONS \ PID
1000 x
1000
P784
10000
0
100.00
10.00
100.00
1.00
100.00
10.00
100.00
1.00
100.00
10.00
100.00
1.00
1000
0
OPTIONS \ PID
10000
0
1
1
10000
0
65535
0
100.000
1.000
1
0
100
0
10000
8000
1.000
1.000
10000
1
2000
1
OPTIONS \ PID
1
1
1
0
1
0
Access via
Keyp.
RS485/
Terminal
BUS/
Opt2-M
Ö
R
-
Ö
R/W
IA
Ö
R/W
ID
0
1
Ö
R/W
IA
Ö
R/W
-
Ö
R/W
-
Ö
R/W
-
Ö
R/W
-
Ö
R/W
-
Ö
R/W
-
Ö
R/W
-
Ö
R/W
-
Ö
R/W
-
Ö
R/W
-
Ö
R/W
ID
Ö
R/W
-
Ö
R/W
-
Ö
R/W
IA
Ö
R/W
-
Ö
R/W
-
Ö
R/W
ID
1
0
Ö
R
-
Ö
R
-
Ö
R/W
-
Ö
R/W
-
Ö
R/W
-
Ö
R/W
-
Ö
R/W
-
Ö
R/W
-
Ö
R/W
-
Ö
R
-
Ö
R/W
-
0
1
Ö
R
QA
Ö
R/W
-
Ö
R/W
-
Ö
Z/R
ID
1
0
Ö
R/W
-
Ö
R/W
-
Ö
R/W
-
Ö
R/W
-
Ö
R/W
-
-
R/W
ID
-
R/W
ID
-
R
QD
Opt2-A
/PDC
R
R/W
R/W
R/W
-
-
-
-
-
-
-
-
-
-
R/W
-
-
-
-
-
R/W
R
R
-
-
-
-
-
-
-
R
-
R
-
-
R/W
-
-
-
-
-
R/W
R/W
R