Preset Functions; Programming Keys; Programming - Nice SLIGHT Instrucciones Y Advertencias Para La Instalación Y El Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 69
8

PROGRAMMING

8.1 - Preset functions
The SLIGHT control unit has a number of programmable functions.These func-
tions are pre-set by the manufacturer to a configuration which should satisfy
most automations.
8.2 - Programming keys
The SLIGHT control unit features three keys that can be used to command the
control unit during tests and programming:
Open
The "OPEN" key enables the user to command the opening of the
gate
or to move the programming point upwards.
s
Stop
The "STOP" key enables the user to stop the manoeuvre, if pressed
Set
for if pressed for more than 5 seconds, it enables users to enter
programming
Close The "CLOSE" key enables the user to control the closing of the gate
or move the programming point downwards
t
Led
Function
L1
Automatic Closing
L2
Close After Photo
L3
Always Close
L4
Stand by
L5
Peak
L6
Pre-flashing
L7
"Close" becomes
"Open partially"
L8
"Slave" mode
During the normal functioning of SLIGHT the LEDs L1....L8 will either be on or off depending on the state of the function they represent. For example L1 will
be on if "Automatic Closing" is active.
TABLE 5 - Level 1 functions (ON-OFF functions)
Description
This function causes the door to close automatically after the programmed time has lapsed.The factory set Pause
Time is 30 seconds, but can be changed to 5, 15, 30, 45, 60, 80, 120 or 180 seconds. If the function is inactive, func-
tioning will be "semi-automatic".
This function enables the gate to be kept open for the necessary transit time only.In fact the "Photo" always causes an
automatic closure with a pause time of 5s (regardless of the programmed value).
The action changes depending on whether the "Automatic closing" function is active or not.
When "Automatic Closing" is inactive: The gate always arrives to the totally open position (even if the Photo disen-
gages first). On release of Photo, automatic closure is activated with a pause of 5s.
When "Automatic Closing" is active: the opening manoeuvre stops immediately after the photocells have disen-
gaged. After 5 seconds, the gate will begin to close automatically.
The "Close after photo" function is always disabled in manoeuvres interrupted by a Stop command.
If the "Close after photo" function is inactive the pause time is that which has been programmed or there is no auto-
matic closing if the function is inactive.
The "Always Close" function will trigger, and the gate will close if an open gate is detected when the power supply
returns. For safety reasons, the manoeuvre is preceded by 5s of flashing. If the function is inactive when the power
supply returns, the gate will remain still.
It is particularly useful in cases when the buffer battery is being used. If this function is active, the control unit will
switch the BLUEBUS output (and consequently the devices) and all the LEDs off one minute after the end of the
manoeuvre.The only LED which will remain on is the BLUEBUS LED which will simply flash more slowly. When a com-
mand arrives, the control unit will reset to complete functioning. If this function is inactive, there will be no reduction in
the consumption.
If this function is activated, the gradual acceleration at the beginning of each manoeuvre will be disconnected. It ena-
bles the peak thrust and is useful whenever static friction is high, e.g. if snow or ice are blocking the leaf. If the thrust is
inactive, the manoeuvre will start with a gradual acceleration.
With the pre-flashing function, a 3 second pause is added between the flashing light switching on and the beginning of
the manoeuvre in order to warn the user, in advance, of a potentially dangerous situation. If pre-flashing is inactive, the
flashing light will switch on when the manoeuvre starts.
By activating this function all "close" commands ("CLOSE" input or radio command "close") activate a partial opening
manoeuvre (see LED L6 on table 7).
By activating this function SLIGHT becomes "Slave": in this way it is possible to synchronise the functioning of two
motors on opposite leaves where one motor functions as Master and the other as Slave; for further information see
"9.1.5 SLIGHT in "Slave" mode.
8.3 - Programming
On the SLIGHT control unit, a number of programmable functions are available.
The functions are adjusted using 3 keys on the control unit: [s] [Set] [t] and
are used by means of 8 LEDs: L1....L8.
The programmable functions on SLIGHT are available on two levels:
Level one: the functions can be adjusted in ONOFF (active or inactive) modes.
In this case, each of the LEDs L1....L8 indicates one function; if it is lit the func-
tion is active, if it is OFF, the function is not active; see Table 5.
Level two: the parameters can be adjusted on a scale of values (from 1 to 8).In
this case, each of the LEDs L1....L8 indicates the set value (there are 8 pos-
sible settings). Please refer to Table 7.
English – 7

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido