Technical Data - Grundfos SL1 Instrucciones De Instalación Y Funcionamiento

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

12. Technical data

Supply voltage
3 x 208 V - 10 %/+ 10 %, 60 Hz
3 x 230 V - 10 %/+ 10 %, 60 Hz
3 x 380 V - 10 %/+ 10 %, 60 Hz
3 x 460 V - 10 %/+ 10 %, 60 Hz
3 x 575 V - 10 %/+ 10 %, 60 Hz
Enclosure class
IP68. According to IEC 60529.
Insulation class
H (356 °F (180 °C)).
Operating pressure
All pump housings have a cast iron ANSI 10 discharge flange.
Dimensions
Discharge flanges are ANSI 2.5", ANSI 3", ANSI 4" or ANSI 6".
Power P
Power P
2
1
[hp (kW)]
[hp (kW)]
3.0 (2.2)
3.9 (2.8)
3.0 (2.2)
3.9 (2.8)
3.0 (2.2)
3.9 (2.8)
3 x 208-230 / 3 x 460
4.0 (3.0)
3.9 (3.8)
4.0 (3.0)
3.9 (3.8)
4.0 (3.0)
3.9 (3.8)
3 x 208-230 / 3 x 460
5.5 (4.0)
6.6 (4.9)
5.5 (4.0)
6.6 (4.9)
5.5 (4.0)
6.6 (4.9)
3 x 208-230 / 3 x 460
7.5 (5.5)
8.6 (6.4)
7.5 (5.5)
8.6 (6.4)
7.5 (5.5)
8.6 (6.4)
3 x 208-230 / 3 x 460
8.0 (6.0)
9.4 (7.0)
8.0 (6.0)
9.4 (7.0)
8.0 (6.0)
9.4 (7.0)
3 x 208-230 / 3 x 460
10 (7.5)
11.7 (8.7)
10 (7.5)
11.7 (8.7)
10 (7.5)
11.7 (8.7)
3 x 208-230 / 3 x 460
12.5 (9.2)
14.1 (10.5)
12.5 (9.2)
14.1 (10.5)
12.5 (9.2)
14.1 (10.5)
3 x 208-230 / 3 x 460
15 (11)
16.9 (12.6)
15 (11)
16.9 (12.6)
15 (11)
16.9 (12.6)
3 x 208-230 / 3 x 460
The resistance in the supply cable depends on the cable diameter.
Resistance per metre of cable: AWG 16 (1.5 mm
Resistance per metre of cable: AWG 14 (2.5 mm
28
2-pole motor
Voltage
Starting method
[V]
3 x 460
Y/D
3 x 575
Y/D
Dual voltage (DOL)
3 x 460
Y/D
3 x 575
Y/D
Dual voltage (DOL)
3 x 460
Y/D
3 x 575
Y/D
Dual voltage (DOL)
3 x 460
Y/D
3 x 575
Y/D
Dual voltage (DOL)
3 x 460
Y/D
3 x 575
Y/D
Dual voltage (DOL)
3 x 460
Y/D
3 x 575
Y/D
Dual voltage (DOL)
3 x 460
Y/D
3 x 575
Y/D
Dual voltage (DOL)
3 x 460
Y/D
3 x 575
Y/D
Dual voltage (DOL)
2
) = 0.013 OHM - CSA/FM
2
) = 0.00830 OHM - CSA/FM
Pump curves
Pump curves are available via the internet on
www.grundfos.com.
The curves are to be considered as a guide. They must not be
used as guarantee curves.
Test curves for the supplied pump are available on request.
It must be ensured that the pump does not operate outside the
recommended operating range during normal operation.
Pump noise emission < 70 dBA
Sound power measurements were carried out according to
ISO 3743.
Sound power was calculated at a distance of 1 metre
according to ISO 11203.
The sound pressure level of the pump is lower than the limiting
values stated in the EC Council Directive 2006/42/EC relating to
machinery.
Cable cross-section
Thermal
protection
[AWG (mm²)]
Thermal switch
14 (2.5)
Thermal switch
14 (2.5)
Thermal switch
14 (2.5)
Thermal switch
14 (2.5)
Thermal switch
14 (2.5)
Thermal switch
14 (2.5)
Thermal switch
14 (2.5)
Thermal switch
14 (2.5)
Thermal switch
14 (2.5)
Thermal switch
14 (2.5)
Thermal switch
14 (2.5)
Thermal switch
14 (2.5)
Thermal switch
14 (2.5)
Thermal switch
14 (2.5)
Thermal switch
14 (2.5)
Thermal switch
14 (2.5)
Thermal switch
14 (2.5)
Thermal switch
14 (2.5)
Thermal switch
14 (2.5)
Thermal switch
14 (2.5)
Thermal switch
14 (2.5)
Thermal switch
14 (2.5)
Thermal switch
14 (2.5)
Thermal switch
14 (2.5)
Cable connection
Conductors/pins
10/10
10/10
10/10
10/10
10/10
10/10
10/10
10/10
10/10
10/10
10/10
10/10
10/10
10/10
10/10
10/10
10/10
10/10
10/10
10/10
10/10
10/10
10/10
10/10

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Slv

Tabla de contenido