Default Values - Pentair INTELLIPOOL AUTOMATION Guía De Instalación Y Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 162
Customizing settings, (restricted)
This menu allows the installer to customize the settings according to the specifics of the equipment. Changing these settings can have serious consequences on
the pool. It is advisable to check the settings changed by a professional. Access to the SETUP MENU and then press simultaneously ESC & ENTER for 3 seconds.
The submenu Instal appears bottom right of the screen (automatically removed after 120 minutes).
SE TTIN GS M E N U
-p H /Dis inf ect. / Te m p
-L a ngua ge
-T i m e
-R a dio
x1
+
ENTER
IN ST A LL. FIL TRA T I ON
A nt i f ree zing :+ 3 ° C
E co = (St anda rt-3 0 % )
T ur bo = (St anda rt+ 3 0 %)
Anti freezing:
Allows you to change the water
temperature from which the
filtration is switched ON forced.
Eco:
Sets the divider ratio of economic
mode.
Turbo:
Sets the multiplier ration of turbo
mode.
16
3s
ESC
S E T TINGS MENU
-p H /Disi nfect./Temp
3s
+
-L a nguag e
-R a dio
ENTER
x2
+
ENTER
p H I N S T A L L A T I ON
I n j e c t i o n t i m e :
15s
M i n t e m p e r a t u r e : 25°C
D a y m a x v o l u m e : 0 .2L
Changing the injection parame-
ters of pH regulator
Injection time:
Time sequence of each pump
injection by correcting pH.
Min temperature:
Temperature below which the
pH correction is not injected.
Day max volume:
Maximum volume allowed for
injection of pH controler (for a
pump at a rate of 1 l / H) to
secure a possible overdose.
Electrolysis / Other : Select the type of disinfectant. O t h er
correspond to a metering pump traitment (bromure, chlorine, active oxygen...)
x4
+
-Time
-Instal
ENTER
x3
+
ENTER
DISINFECTANT INSTAL.
Injection time: 15s
Min temperature :15°C
Day max volume :0.5L
Changing
the
disinfectant
injection parameters except salt
chlorinator (injection of bromine,
oxygen)
Injection time:Time of each
injection sequence of
disinfectant.
Min temperature:
Temperature below which the
disinfectant is not injected or
electrolyzer is shut down to
reduce wear on the plates.
Day max volume: Maximum
volume allowed for injection pH
corrector (for a pump at a rate of
1 l / H) to secure a possible
overdose.
Electrlysis
Other
-Filtration
-pH
-Disinfect.
-Aux1

Default values

x4
+
ENTER
AUX1 INSTALLATION
Robot mode
Backwash mode : No
Backwash Timer: 30s
Changing parameters using the
output Aux1
Robot mode : Select Yes to
asign the output Aux1 is used to
drive robot cleaner and so
launch filtration.
Backwash mode : Select Yes
to drive a back wash pneumatic
push pull valve
Backwash timer : Back wash
duration
: No