ALARM MODE - Modification of alarm setpoint values
With this mode you can modify the setpoint value of:
- the pH high alarm (factory pre-setting 7.9)
- the pH low alarm (factory pre-setting 6.7)
- the conductivity high alarm (factory pre-setting 1200μS)
- the conductivity low alarm (factory pre-setting 50μS)
- the RedOx/ORP high alarm (factory pre-setting 800 mV)
- the RedOx/ORP low alarm (factory pre-setting 500 mV)
1 - Push the switch to alarm mode (rear face of indoor display). note: All these values remain stored in a battery change
2 - Set the value following the navigation operating principle.
3 - When the last modification is valited, set the switch back to ON mode
1
calib on
alarm
To restore all the device's default values, press and hold (4 s) RESET with a paper clip on the
rear of the remote display.The operation is validated by a long beep.
2
1
2
1 = escape
- go back to previous stage without confirming modifications
2 = move down / decrease
- browse downward in scrolling menus or decrease values in numerical sections
3 = move up / increase
- browse upward in scrolling menus or increase values in numerical sections
4 = validate
- access the parameter displayed or validates modifications and goes back to the previous menu
3
4
33