Add A New Radio Relay - Pentair INTELLIPOOL AUTOMATION Guía De Instalación Y Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 162
pH value
pH is a (unitless) quantity measuring the acidity (0 to 7) or alkalinity (7 to 14) of the pool. pH is the concentration of hydrogen ions. For a pool, the
generally advised ideal pH is close to 7.3 (to be confirmed with your pool dealer, according to your installation).
The accuracy of the pH measurement is strongly tied to regular maintenance of the pH probe. It is advisable to check regularly for any clogging,
and to calibrate it before the summer season (see p.33). The pH high and low alarm setpoint values are preset in the factory to 6.7 and 7.9. These
values can be modified via alarm mode (see p.33).
0
1
2
3
pH has reached the maximum alarm value
(factory pre-setted 7.9 modifiable via the alarm menu, see p.33)
pH has reached the minimum alarm value
(factory pre-setted 6.7 modifiable via the alarm menu, see p.33)
measured pH value
(display limited between 0 and 9.9)
EXCESSIVELY HIGH OR LOW pH CAUSES SKIN IRRITATION
> Make sure that:
- the bottle has been removed from the pH probe
- the pH probe has been calibrated in the last 6 months (see p.35)
- the pH probe is not clogged
> Manual regulation: apply some "pH-" or "pH+" product, depending on the pH deviation.
> Automatic regulation: verify that the equipment is working properly

Add a new radio relay

This RADIO mode enables the following to be added a second radio relay to cope with demanding radio range situations (lay of the land, very long
distances...).
1 - Press RESET briefly (0.5 s) with a paper clip at the back of the remote display. note: Pressing and holding ( >4 s until the beep) activates a
setpoint values reset. > The remote display will then display «radio».
2 - Take off the pot by pulling the tab on the radio relay.
3 - Place the jump in OFF position to avoid to perturb the air temperature values of the radio relay#1, see p3.
4 - Remove the battery insulation film.
5 - Reconnect the battery holder.
6 - The red LED flashes max 120s untill the radio relay is recognised > Put the container's cover back on.
1
4
4
5
6
7
= pH < 0
2
5
8
9
10
pH
pH compliant with alarm setpoint values
(factory pre-setted from 6.7 to 7.9)
pH outside alarm setpoint values
(Mini or Maxi indicate whether
the value is too low or too high)
= pH > 9.9
11
12
13
3
OFF
6
31
14

Publicidad

Tabla de contenido
loading

Tabla de contenido