Pentair INTELLIPOOL AUTOMATION Guía De Instalación Y Usuario página 26

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 162
IntelliFlo® menu
IntelliPool
enables you to obtain the most efficient and economic use of your IntelliFlo
®
IntelliFlo
equipped with the VS, VF or VSD variable frequency drive.
®
Before setting up the speeds in the IntelliPool
nal speed settings.. You can do this before the actual installation or by disconnecting the IntelliFlo
the pump keypad to quickly change speeds on the pump. Consult your IntelliFlo
your pump. (IntelliFlo
VF customers need to use the manual button using the 'ste speed' command.)
®
IntelliFlo : 45000
IntelliFlo speed range
Electrolysis filtration speed
Heating filtration speed
Shock mode speed
Shock mode speed
Backwash filtration speed
Sequence duration :
IntelliFlo - Warning
1 2 3 4 5 6 7 8
#2: DRIVE TEMPERATURE WARNING'
Save modifications
Comments about current alarms displayed (hover the mouse
on the concerned alarm).
IntelliChlor : 45000
Running duration cover closed
Save modifications
IntelliChlor - Warning
1 2 3 4 5 6 7
#2: LOW SALT'
24
menu on IntelliPool
®
1200
Min :
rpm
3000
Min :
rpm
1300
Min :
rpm
3000
Min :
rpm
2400
Min :
rpm
No change
AUX 2 Setpoint :
rpm
No change
AUX 3 Setpoint :
rpm
No change
AUX 4 Setpoint :
rpm
2600
Setpoint :
rpm
0m 10s
0h 15min
/day
8
pump. The system can operate with every type of
®
, it is advised to run an operational test in order to establish the most functio-
®
manual for precice explanation on how to change speeds on
®
Mimimum speed: find out the mimimum speed still generating sufficienbt
flow in the pool. IntelliPool
®
can establish this speed the better the energy savings.
Maximum: speed: this is generally the speed required for backwashing, the
pump will not allow higher speeds in order to prevent damage to the pool
system.
Heater: your heatpump will require a mimimum flow; select a speed at wich
the heatpump can operate. You can adjust the speed upwards until the
heatpump compressor is activated. Set the speed another 5% higher.
Salt Chlorinator: your salt chlorinator will require a mimimum flow. Deter-
mine what RPM is required for your chlorinator to be activated and set the
menu at a 5% higher value.
Aux speed: for auxiliary features 3 options are possible (selectable in the
scroll menu)
1. no change: pump will continue normal filtration speed while aux feature is
active (example: garden lights).
2. OFF: pump will stop while aux is active ( example robotic cleaner).
3. set specific RPM: the pump will run at a specific RPM while aux feature is
active (example: fountain).
Automatic backwash valve: if the aux feature is set-up as an automatic
Backwash valve, specific BW speed and time can be set in this section.
With these setting in place IntelliFlo will run at the lowest, most economical
speed, but will increase this speed only when required for the specified
functions.
Limited duration of chlorinator running in presence of cool cover
Comments about current alarms displayed (hover the mouse on the concer-
ned alarm).
Communication cable. This way you can use
®
will not run lower then this speed. The lower you