General Operation; Internet Relay - Pentair INTELLIPOOL AUTOMATION Guía De Instalación Y Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 162

General operation

The Probe unit located in the technical room collects information on water quality and communicates them to the Control center. Also situated in
the technical room, the Control center activates the different pool functions. For IntelliFlo® and IntelliChlor® this information is sent using an
RS485 bus. This way IntelliPool® also retrieves information and feedback from IntelliPool® and IntelliChlor®. Using a proprietary wireless protocol
the control center sends and receives information and commands from the other system components. The Internet relay allows remote access to
the system using PC, tablet or smartphone. The Indoor display informs the pool owner on the pool's main parameters, while the Outdoor remote
control enables activation of lights and a water feature from the side of the pool. The Radio relay assures optimum radio communication between
the components while at the same time collecting ambient air temperature. In this setup the system contains all the necessary input and control
to assure a trouble free pool environment.
Salt chlorinator
Dosing & measuring
equipment
Specific IntelliFlo® Settings for VSD drives
IntelliFlo
VS and VF do not require specific settings on the pump itself. For IntelliFlo
®
- disable the antifreeze function in the pump
- set the miminum and maximum speed to the same values as in the IntelliPool
pump manually.
- determine if you want the priming function to be activated. Consult the VSD manual on this feature. When enabled on the pump, priming setting
as determined on the pump drive wil become active. Please note this can lead to unwanted results in combination with water features!
Caution: IntelliPool
will always control the pumps keypad; it is not possible to stop the pump from the keypad while IntelliPool
®
active. Use IntelliPool
or in case of emergency the pump's main power switch to stop the pump.
®
4
Internet
Relay
Indoor
Display
Control Center
1 2/ 07 /1 3 15:23:48
W at er t emp:+24.0°C
p H: 7, 3
ORP:629mV
C on d: 55 71uS 3.51g/l
ESC
CONTROL CENTER
ENTER
Heating
Filter
Radio Relay
Power Unit
REDOX - PH
PROBE UNIT
TEMPERATURE
CONDUCTIVITY
Automatic Valve
Pump
VSD however make sure to:
®
menu in order to obtain similar protection when operating the
®
Remote Control
Under Waters Light
is
®

Publicidad

Tabla de contenido
loading

Tabla de contenido