Malfunctions; Corrective Action - SATA spray master RP Instrucciones De Servicio

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 137
Operating Instructions SATA spray master RP
EN
Notice!
In rare cases, it may be necessary to dismantle some parts of the spray
gun to clean them thoroughly. If dismantling should be necessary, this
should be limited just to the parts whose function brings them in contact
with the material.
■ Purge spray gun thoroughly with thinner.
■ Clean air cap with a paint brush or brush.
■ Lightly grease moving parts with high performance grease.

11. Malfunctions

The malfunctions described below may only be remedied by trained per-
sonnel.
If it is not possible to remedy a malfunction with the described corrective
actions, send the spray gun to the SATA customer service department
(address see chapter 16).
Malfunction
Jerky spray fan pat-
tern (wobbling / splut-
tering) or air bubbles
in the gravity flow cup.
Spray pattern too
small, slanted,
one-sided or split.
Round / flat fan control
cannot be regulated.
Spray gun does not
shut air off.
132
Cause
Fluid tip not tightened. Tighten fluid tip with
Air cap holes clogged
with paint.
Damaged fluid tip
(fluid tip aperture).
Control has been
turned counterclock-
wise over the limit;
spindle loose in gun
thread.
Air piston seat
clogged.
Air piston worn.

Corrective action

universal spanner.
Clean air cap. Heed
cleaning instructions
(see chapter 10).
Check fluid tip for any
signs of damage, re-
place nozzle set if nec-
essary.
Unscrew control with
open-end spanner;
make serviceable or
replace completely.
Clean air piston seat.
Heed cleaning instruc-
tions (see chapter 10).
Replace air piston and
air piston packing.