US
■ Push control knob towards paint spray gun until it audibly engages.
■ Turn ventilation valve [1-2] briefly and check if the pressure gauge
returns to the desired set pressure.
Adjusting the spray gun internal pressure
Information!
When adjusting the spray gun internal pressure using an external pres-
sure reducer, the air micrometer [# 53603] must be fully open (in vertical
position).
Information!
For the best accuracy, the spray gun internal pressure can be set using
the SATA adam 2.
Information!
If the required gun input pressure is not present, increase the pressure
in the compressed air circuit.
Excess input pressure will cause excess removal forces.
■ Pull trigger [1-12] all the way off.
■ Adjust according to one of the following adjustment options. Adhere to
the maximum gun input pressure (see 7).
■ Adjusting via SATA adam 2.
■ Adjusting via external pressure reducer.
■ Move the trigger to the start position.
Adjusting the material flow rate
Information!
There will be less wear on the paint nozzle and paint needle if the ma-
terial flow control is fully open. Select the nozzle size depending on the
spray medium and working speed.
The material flow rate and thus the needle lift can be variably adjusted
using the adjustment screw [1-4].
■ Loosen counter nut.
■ Pull trigger [1-12] all the way off.
■ Adjust material flow rate using adjustment screw [1-4].
■ Tighten counter nut by hand.