Procedural verifications - INFO Mode
TEST
x5 s
INFO mode may be used to view certain parameters measured by the CTRL controller.
Press and hold the TEST button for 5 seconds from the "View command signals and safety devices" mode with the motor
stationary. The controller displays the following parameters in sequence:
Parameter
Function
.
View for 3 s the firmware version of the control unit.
View barrier position (ENCODER data) at time of test, in motor revolutions.
(example:
View total length of programmed travel, in motor revolutions (e.g.:
View motor speed, in revolutions per minute (rPM).
View current absorption of motor, in Amperes (e.g.:
If the motor is stationary, the current absorption value is 0.
System OK indicator. To check for overloading (e.g.: too many utilities connected to 24 V output) or if the mains voltage is
too low, compare the parameters read with values indicated as follows with the motor stationary:
mains voltage = 230 V AC (nominal), bUS=
mains voltage = 207 V AC (-10%), bUS=
mains voltage = 253 V AC (+10%), bUS=
Indicates time taken by motor to detect an obstacle, as set with parameter
E.g. .
= 1 s / .
Displays a number which indicates the status of the control unit (INTERNAL USE - ROGER TECHNICAL ASSISTANCE)
Displays a number which indicates the status of the SLAVE control unit (INTERNAL USE - ROGER TECHNICAL ASSISTANCE)
and visible only on the MASTER control unit; on the SLAVE control unit,
Number of RS485 communication errors (it gets reset by pressing "arrow down"
board circuit level.
Number of communication protocol errors (it gets reset by pressing "arrow down"
It can highlight:
• problems at connection cable level LNA/LNB/COM (reduced section, excessive length, closeness to cables with
switching loads)
• difficulties in communicating with the SLAVE control unit.
Indicates the state of the automation system (open/closed).
automation system opening (motor active).
automation system closing (motor active).
automation system completely open (motor not actives).
automation system completely closed (motor not actives).
Indicates activation of the obstacle detection system.
obstacle detection activated.
mains voltage too low or overload.
motors overcurrent.
malfunction detected, reduce acceleration and speed settings, and check spring setting.
• Use the + / - buttons to scroll through the parameters. When the last parameter in the sequence is reached, press the -
button to return through the previous parameters.
• In INFO mode, the automation system may be activated to test operation in real time.
• Press and hold the TEST button for a few seconds to exit INFO mode.
88
.
= barrier installed on the right;
.
.
.
= 0.12 s (120 ms). Ensure that the manoeuvre time is more than 0.3 s.
TO QUIT THE
...
INFO MODE
.
= barrier installed on the left).
. = 37.8 motor revolutions).
. = 16.5 A).
, in seconds.
is always displayed.
): this could highlight problems at
).
TEST
1 click