6

Description of connections

To access the control unit. remove the barrier head.
Figure 1-2-3 shows connection diagrams.
6.1

Typical installation

4
5
1
1
Power supply
2
Photocell - Receiver F4ES/F4S
3
Photocell - Transmitter F4ES/F4S
Key selector R85/60
4
Keypad H85/TTD - H85/TDS (connecting to control panel to decoder
board H85/DEC - H85/DEC2)
Barrier open indicator
5
Power supply 24V DC 3W max
SUGGESTIONS: with existing installations, we recommend checking the cross section of the cables and that the
cables themselves are in good condition.
3
2
Recommended cable
H07RN-F 3x1,5 mm2 double insulated cable
2
Cable 4x0,5 mm
(max 20 m)
2
Cable 2x0,5 mm
(max 20 m)
Cable 3x0,5 mm
2
(max 20 m)
Cable 3x0,5 mm
2
(max 20 m)
Cable 2x0,5 mm
2
(max 20 m)
3
2
63