16
Alarms and faults
PROBLEM
ALARM SIGNAL
The barrier does
POWER LED off
not open or close.
POWER LED off
Example:
POSSIBLE CAUSE
No power.
Fuses blown.
Fuse F1 blown or damaged.
This message is not visible if con-
troller is in battery power mode.
Input mains power voltage fault.
Controller initialisation failed.
Overcurrent detected in inverter.
Incorrect
connection
between
SEC1 and SEC2 of the transformer.
Travel data acquisition error.
Calibration procedure failed
(
).
Automation system position
selection modification message
with parameter
.
Motor not connected.
BreakAway system alarm.
Configuration parameter
error.
CORRECTIVE ACTION
Check power cable.
Replace fuse.
Always disconnect from mains power before removing
and refitting fuses.
Replace fuse.
Always disconnect from mains power before removing
and refitting fuses.
Disconnect from mains power, wait 10 seconds then
reconnect to the mains and switch on.
We recommend replacing the control unit if the prob-
lem persists.
Press the TEST button twice or perform 3 command
requests in succession.
Swap the connection between SEC1 and SEC2.
Check that the spring is balanced correctly with the
barrier unlocked.
Press TEST and check if any safety devices are in
alarm state.
Repeat acquisition procedure.
Allow the indicated calibration times to elapse during
self-acquisition.
Before re-closing the release lock cover, ensure that
on the display will flash
procedure.
SX
Motors for barriers are factory configured for right
hand opening barriers
(position of barrier rela-
tive to passage seen from inspection hatch side). If the
position is changed and message
• Move the boom 45° degree.
• Adjust the spring position correctly for the required
opening direction.
• Press and hold PROG until
appears on the display.
Repeat acquisition procedure.
Check the motor cable.
• Check the setting of par.
.
• Check the correct ACS/BA/60 system connection
to the control unit.
• Re-engage the boom.
• Consider replacing the boom if it is damaged.
Set configuration value correctly and save.
...Continued
. Repeat acquisition
DX
is displayed:
disappears and
85