4.3.9.2. About the Pre-Feeder Mechanism
The pre-feeder mechanism consists of left and right pre-feeder wheels located
directly to the right of the feed belt and the MFD override LED and the MFD
override button (see Figure 4-47).
Pre-Feed MFD Override Button
Pre-Feed MFD Override LED
The pre-feeder mechanism can only be activated via the MFD override button
when the machine is in a jammed or paused state. In the event of a jam, the
Pre-Feeder LED will flash green at a 0.5 second interval; alerting the operator
that it may be selected for use to re-feed any rejected or jam sorted sheets. If
the operator activates the Pre-Feeder, the LED will be solidly lit green and the
Pre-Feeder arms will raise to allow the item(s) to be placed under them.
Selecting the Pre-Feeder again will cause the Pre-Feeder LED to shut off, the
jam dialogue to disappear from the screen, the pre-feed nip wheels will lower to
the top of the item(s) and feeding will resume.
To use the Pre-Feeder in the event of a jam:
1. When the Pre-Feed LED is flashing, press the Pre-Feed MFD Override
button.
2. Wait for the pre-feeder arms to be raised and the Pre-Feed LED to be
solidly lit.
3. Place all sheets to be fed under the pre-feeder arms.
4. Press the Pre-Feed MFD Override button or hit the continue button in the
jam dialogue.
The jam dialogue should disappear, the Pre-Feed LED will no longer be illu-
minated, and feeding should resume at the auto-feeder.