Table 5: Reasons for jams (continued)
Vertical Turn Sensor
Missing
Stacker Entry Sensor
Missing
Bin 2 Gate Sensor
Missing
Feed Entry Multifeed
Sensor Blocked
Feed Input Multifeed
Sensor Blocked
Unexpected Piece at
Stacker Entry Sensor
Unexpected Piece at Bin
2 Sensor
Invalid Piece Complete
Response
Piece Thickness Sensor
Null Below Minimum
Piece Thickness Sensor
Null Above Maximum
Results when the controller is expecting to see a
piece pass by the vertical turn sensor but it has
not within the time period that we are expecting
it.
Results when the controller is expecting to see a
piece pass by the stacker entry sensor but it has
not within the time period that we are expecting
it.
Results when the controller is expecting to see a
piece pass by the bin 2 gate sensor but it has
not within the time period that we are expecting
it.
The Feed Entry MultiFeed Sensor is blocked.
The Feed Input MultiFeed Sensor is blocked.
Results when a piece is detected at the stacker
entry sensor that the software was not
expecting. This is usually caused by a piece that
was intended to go to the stacker bypass bin but
did not make the correct decision in time. A gate
that did not fire properly can also cause it.
Results when a piece is detected at the bin 2
sensor that the software was not expecting. A
gate that did not fire properly usually causes this
to occur.
Results when an invalid piece id is received
from the host upon piece completion.
Results when the thickness sensor is lower than
the minimum null defined in the machine
parameters.
Results when the thickness sensor is greater
than the maximum null defined in the machine
parameters.