Descargar Imprimir esta página

Opex Falcon+ Manual Del Operador página 266

Ocultar thumbs Ver también para Falcon+:

Publicidad

Idiomas disponibles

Idiomas disponibles

A.1.3. Overall System Performance Measures Statistics
The table below lists the terms that appear in the Overall System Performance
Measures section of the statistics report.
Table 2: Overall System Performance Measures terms
Term
Input
Output
Jam Rate
Rejects
Feed Rate
Output Rate
Jam Clear
Time
Reference
Feed Rate
Definition
Number of pieces fed into the machine.
Number of pieces successfully processed by the machine.
This number is figured by subtracting the number of rejects
from the number of pieces input.
Number of jams per run. The formula for the Jam Rate is:
Jam Rate = Input
Jams
Number of pieces rejected.
Number of pieces per hour the Falcon+ is currently feeding.
The formula for the Feed Rate is:
Feed Rate =
Active Job Time (seconds)
Number of pieces per hour the Falcon+ is processing. The
formula for the Output Rate is:
Output Rate =
Active Job Time (seconds)
Average time the Falcon+ was halted while the Operator
was clearing a jam. The formula for the Jam Clear Time is:
Jam Clear
Time (seconds) =
Number of pieces fed into the Falcon+ per hour. The
formula for the Reference Feed Rate is:
Reference Feed Rate =
Run Time (seconds) + (Jams * Ref. Jam Clear Time (seconds))
Falcon+ Operator Manual
OPEX Corporation
Input * 6600
Output * 6600
Jam Time (seconds)
Jams
Input * 6600
133

Publicidad

loading

Productos relacionados para Opex Falcon+