If the operator pauses the machine, the Pre-Feed LED will flash green at a
0.5 second interval; alerting the operator that it may be selected to inject a
single or multiple items into the machine. If the operator activates the Pre-
Feeder, the LED will be solidly lit green and the pre-feeder arms will raise to
allow the item(s) to be placed under them. Selecting the Pre-Feeder again
will cause the machine to exit the paused state, lower the Pre-Feed nip
wheels onto the top of the item(s) and feeding will resume.
To use the Pre-Feeder during the paused state:
1. When the Pre-Feeder LED is flashing, press the Pre-Feed MFD Override
button.
2. Wait for the Pre-Feeder arms to be raised and the Pre-Feed LED to be
solidly lit.
3. Place all sheets to be fed under the pre-feeder arms.
4. Press the Pre-Feed MFD Override button or press the resume button.
The Pre-Feed LED will no longer be illuminated, and feeding should
resume at the auto-feeder.
Operation
Falcon+ Operator Manual
OPEX Corporation