Product Description; General Information; Technical Data - Daikin AHT LISBOA Serie Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 117
AHT Cooling Systems GmbH | en
3

Product description

3.1

General information

AHT products comply with EU Regulation 1907/2006
(REACH) on the Registration, Evaluation, Authorisa-
tion and Restriction of Chemicals.
Neither refrigerant R-290 nor the blowing agent
pentane have an ozone depletion potential (ODP).
R-290 has a very low global warming potential (GWP)
of 3.
3.2

Technical data

Important technical data can be found on the power
rating plate [see } Chapter 3.2.1].
Observe the appliance-specific information on the rat-
ing plate.
Parameter
Value
See →Appliance model over-
External dimensions
view
See →Appliance model over-
Appliance weight
view
Airborne noise emit-
ted/emission sound
< 70 dB(A)
pressure level
Refrigerant
Propane (R-290)
M-package temper-
ature class (product
temperature class)
S
pursuant to EN ISO
23953-2
Maximum load
Parameter
Value
Sticker at the top right of the in-
Storage racks
side of the equipment cover
next to the power rating plate
Display shelf top
(Standard depth=
100 kg/m²
400 mm)
Display shelf bottom
(Standard depth=
100 kg/m²
550 mm)
Bottom shelf
100 kg/m²
Electrical connection
Parameter
Value
rated voltage
rated frequency
220 – 240 V
50 Hz
– Power supply
unit and light
Plug types
National versions
Minimum cross-sec-
tion for appliance
1.5 mm²
connecting cables
Minimum cross-sec-
tion for light connect-
1.0 mm²
ing cables
416433_1_0720
Parameter
Value
Connecting cable
3-pin cable
Bus system
Parameter
Value
Bus connection (Op-
RJ12 socket CAN bus system
tional)
Fusing
[see } Chapter 8.2]
Rated cur-
Fault
Type
rent [A]
current
[mA]
Circuit breaker (LS/CB)
10
-
-
(1 appliance)
16
(2 appli-
-
-
ances)
10
-
-
(light)
Residual current circuit breaker (FI/RCCB/GFCI)
G (short-time delay)
A (pulse current-
sensitive)/
40
30
F (mixed frequency-
sensitive)/
B (universal cur-
rent-sensitive)
Residual current circuit breaker with overcurrent pro-
tection FI-LS/RCBO (alternative to RCCB and CB)
G (short-time delay)
A (pulse current-
sensitive)/
10
30
F (mixed frequency-
(1 appliance)
sensitive)/
B (universal cur-
rent-sensitive)
G (short-time delay)
A (pulse current-
16
sensitive)/
(2 appli-
30
F (mixed frequency-
ances)
sensitive)/
B (universal cur-
rent-sensitive)
G (short-time delay)
A (pulse current-
sensitive)/
10
30
F (mixed frequency-
(light)
sensitive)/
B (universal cur-
rent-sensitive)
Recommended light colours
Parameter
Value
Red
076 (meat)
x = 0,4142
Red
y = 0,3553
Product description | 3
Tripping
charac-
teristic
C (slow-
acting)
C (slow-
acting)
C (slow-
acting)
-
C (slow-
acting)
C (slow-
acting)
C (slow-
acting)
33 / 500