Transport And Storage - salmson IMMERSON D400 Instalacion Y Puesta En Servicio

Bombas de perforacion immerson
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

ENGLISH
1. GENERAL
1.1 Applications
• For boreholes and deep wells.
• For the pumping and distribution of water :
- for household use (drinking water supply),
- for agricultural use (sprinkling, irrigation, etc,...),
- for industrial use (pressurization, etc,...).
1.2 Technical data
50 Hz
• Temperature range
• Flow rate up to
• Head up to
• Maximum sand content
• Discharge Ø
• Maximum immersion
• Motor rating up to
60 Hz
•Temperature range
• Flow rate up to
• Head up to
• Maximum sand content
• Discharge Ø
• Maximum immersion
• Motor rating up to
2. SAFETY
Read this instruction carefully before installing and starting up. Pay
special attention to the points concerning the safety of the equip-
ment as regards the intermediate or final user.
2.1 Symboles des consignes du manuel
Potential risk for the safety of the persons.
Instructions relating to electrical risks.
The non-respect of this instruction may involve a
CAUTION !
damage for the material and its operation.

3. TRANSPORT AND STORAGE

When receiving the material, check that there has been no damage
during the transport. If any defect has been stated, take the required
steps with the carrier within the allowed time.
If the delivered material is to be installed later on,
store it in a dry place and protect it from impacts
CAUTION !
and any outside influences (humidity, frost etc...).
4. PRODUCTS AND ACCESSORIES
4.1 The pump
- Immersed for 4" borehole, multistage with radial or semi-axial impel-
lers according to the types of pumps.
- Coupling motor "NEMA".
- Non-return valve integrated inside the pump.
- Rustless materials.
4.2 The motor
- NEMA endshield 4".
- Watertight stator covered with resin.
- Bearings lubricated with a non-polluting water.
- Stainless steel materials (or protected with a stainless steel cover).
- Removable cable.
: + 3 °C to + 30 °C
: 24 m
/h
3
: 300 m
: 5 kg/m
3
: 1"1/4 & 2" depend product
: 350 m
: 7,5 kW
: + 3 °C to + 30 °C
: 28 m
/h
3
: 280 m
: 5 kg/m
3
: 1"1/2 & 2"depend product
: 350 m
: 7,5 kW
Motor
Insulat. Speed
Size
Class
B
50 Hz
4"
B
B
60 Hz
4"
B
- Protection class : IP 68
- Maximum starts per hour : 20
- Min. cooling flow : 8 cm/sec.
4.3 Accessories (as option)
• Motor overload release • Control box or cabinet and dry running
electrode protection • Custom-made cabinets • Electric cables •
Heat shrinkable junctions • Bladder tank • Pressure gauges • Motor
cooling sleeve • Valves • Non-return valves • YN7112 box • ACSON
• PMS box...
4.4 Product alternative version
PAP pumps (ready-to-pump) supplied with:
- Single-phase motor with permanent capacitor,
- Starting box with thermal protection of motor (built-in capacitor),
- Power cord between pump and box,
- Stainless steel rope to support the pump,
- Power cord with standardized plug.
5. INSTALLATION
Pumps can operate in vertical or horizontal position.
5.1 Mounting
- The borehole or pumping station have to be achieved according
to good practice and professional rules.
- Check that the water supply into the borehole or the well is appro-
priate relating to the output of the pumps set.
- The pump is lowered using a block and tackle with a cable and tripod,
or for heavy pumps, using a winch truck for borehole applications.
- To ensure that the pump never runs dry, check that the water level
never goes below the discharge port even in periods of low water
levels.
For installation into a deep well (well diameter lar-
CAUTION !
ger than borehole) or for horizontal operation we
recommend using a cooling sleeve around the pump and the motor
to maintain an appropriate cooling of the motor (See FIG. 5).
- Ensure that the inserted tube into the bore has a constant diame-
ter and allows a free lowering of the unit.
- Do not lower the unit with help of the electric cable or by the help
of the PAP rope.
- Perform all electric connections of conductors with the supply
cable of the motor before lowering the unit.
In a borehole insallation, the pump have to be
CAUTION !
hanged by it's conduit, on the top of the borehole,
with the help of an clamp (See FIG. 4 - item 16).
Do not hang PAP pump by the inox rope. This rope shall only be used
in case of pipe damage.
- In final position, the unit must be hanging at least 0.30 m above the
bottom of the borehole or the well (See FIG. 4).
- It is required to fix the location identification plate closed to the bore-
hole to ensure the availability of all characteristics of the installation.
- Before lowering (and while lowering into a deep borehole) measu-
7
TECHNICAL DATA
Phases
Capacitor
rpm
1~230 V
Permanent or starting
2860/
(option
+ permanent accor-
2900
220 V)
ding to version
2840/
3~380-
2880
400-415V
Permanent or star-
3430/
1~230 V
ting + permanent
3470
according to version
3~440-460
3430/
3480
(option 380-230V)

Publicidad

Tabla de contenido
loading

Tabla de contenido