Sensor
● Type: Nonintrusive, externally mounted
● Temperature Range: -40°C to +120°C (-40°F to +250°F)
Dimensions
● 236 cm (9.31 in) x 287 cm (11.31 in)
● Net weight: 4.1 kg (9.0 lbs.) max
Liquid Temperature
● Standard: -40°C to +120°C (-40°F to +250°F)
● Optional: -40°C to +230°C (-40°F to +450°F)
Liquid Type
● Water
● Multiple Crude Oils
● Light Crude only
● Heavy crude only
● Multiple Finished Products
● Gasoline Only
● Kerosene
● Jet Fuel
● Diesel
● Multiple Fuel Oils
● Heavy Fuel Oils
● Liquefied Gases
● Other (Define Liquid name and Vs)
Unit Repair and Excluded Liability
All changes and repairs must be done by qualified personnel, applicable safety regulations
must be followed. Please note the following:
● The user is responsible for all changes and repairs made to the device.
● All new components must be provided by Siemens Industry, Inc.
● Restrict repair to faulty components only.
● Do not re-use faulty components.
FUS1010 IP65 NEMA 4X
Operating Instructions, 7/2010, A5E03086486-02
Appendix A
59