4.5.4 Control panel assembly
(fig. 6/c)
- Secure the control panel to the
transversal element (D) with the
four self-threading screws supplied.
- Inser t t he bulbs of t he saf e ty
thermostat (TS), boiler thermostat
(TC), minimum thermostat (TM) and
of the thermometer in the probe-
POWER SUPPLY
ALIMENTAZIONE
holder well (1).
- Remove the bracket (2) mounted on
the smoke flue gas chamber and
inser t t he bulb of t he f lue gas
thermostat (TF).
- Perform the electrical connections
of the door microswitch, the fan and
the earth cable of the control panel.
The fan socket and plug are already
assembled when they are supplied.
D
The Faston connector of the control
panel's ear t h cable mus t be
inserted on the earth connection on
the transversal element (D). Carry
out the electrical connections as
indicated in the diagram in fig. 3/a.
WARNING: When the fan cable is
connected to the plug, also open
the socket to make sure the phase
and neutral are not inverted. .
1
2
TF
Fig. 6/c
ENG
ES
13