PROBLEM
ALARM SIGNAL
The barrier does
not
open
or
close.
Acquisition pro-
cedure does not
complete
cor-
rectly.
Barrier does not
perform desired
manoeuvre.
The
barrier
opens/closes for
a short distance
and then stops.
The remote con-
trol has limited
range and does
not work with
the
automation
moving.
The flashing light
is not working.
Barrier open indi-
cator lamp does
not work.
N.B.: Press the TEST button to temporarily cancel the alarm.
The next time a command is received, the alarm reappears on the display if the problem has not been resolved.
POSSIBLE CAUSE
Encoder 2 not connected.
Severe encoder 1 malfunction.
Severe encoder 2 malfunction.
Encoder 1 malfunction.
(EnE5)
Operation in battery mode.
Encoder 2 malfunction.
Operation in battery mode.
Encoder 1 calculation error.
Encoder 2 calculation error.
Inverter overheat protection triggered. Function is restored automatically within 2 minutes.
Flat batteries.
(btLO)
Motor calibration failed.
TEST button pressed accidentally.
Safety devices in alarm state.
Excessive voltage drop.
Incorrect setting of parameter
Incorrect setting of parameter
Incorrect values for installation type.
Incorrect spring setting.
Battery operation management (par.
different than
Radio signals are impeded by metal
structures and reinforced concrete
walls.
Flat batteries.
Bulb / LED blown or flashing light wires
disconnected.
Bulb blown or wires disconnected.
CORRECTIVE ACTION
Check connection to encoder.
Replacing the encoder is recommended if the problem
persists.
Press TEST button. If the error code is displayed again,
switch off the controller unit, wait 5 seconds and switch
on again. Replace the encoder if the problem persists.
Press TEST button. If the error code is displayed again,
switch off the controller unit, wait 5 seconds and switch
on again. Replace the encoder if the problem persists.
Press TEST button or perform 3 command requests in
succession. Replace the encoder if the problem per-
sists.
Batteries almost flat.
Press TEST button or perform 3 command requests in
succession. Replace the encoder if the problem per-
sists.
Batteries almost flat.
Repeat acquisition procedure.
Repeat acquisition procedure.
Wait for mains power to be restored.
Repeat acquisition procedure.
If the problem persists, check the cable connecting en-
coder 1 to the motor.
Check that the motor turns without impediment. Con-
tact technical support in case of any problems.
Repeat acquisition procedure.
Check connections of safety devices.
Repeat acquisition procedure; check mains voltage.
.
Select the correct installation position with parameter
. Repeat acquisition procedure.
.
Check type of boom and set parameter
Repeat acquisition procedure.
Set values of parameters
lation type.
See barrier instructions for balancing springs.
Change the value of the parameter
) not detected.
Install the antenna.
Replace the radio control batteries.
Check LED circuit and/or connector wires.
Check the bulb and/or wires.
correctly.
and
correctly for instal-
.
77