Parameters menu

PARAMETER
PARAMETER
VALUE
Boom type selection
WARNING! An incorrect setting may cause severe damage or injury.
Use the standard parameter values indicated in the table in relation to the boom length selected.
Elliptical cross section boom BA/68/3 - maximum length 3 m.
Round cross section boom BA/60/3 - maximum length 3 m.
Automatic closing after pause time (from barrier completely open position).
N.B.: This parameter is not visible if the value of parameter
Disabled.
From 1 a 15 automatic closure attempts after activation of photocells.
Once the number of attempts set is reached, the barrier remains open.
The barrier tries to close indefinitely.
Automatic closing after mains power outage
Disabled. The barrier does NOT close automatically when mains power is restored.
Enabled. If the barrier is NOT completely open, when mains power is restored, the barrier closes after a
5 second pre-manoeuvre warning signalled with the flashing light (independently of the value set with
parameter
Step mode control function selection (PP)
Open-stop-close-stop-open-stop-close...
Condominium function: the barrier opens and closes after the set automatic closing time.
The automatic closing timer restarts if a new step mode command is received with the boom in the com-
pletely open position. Step mode commands are ignored while the barrier is opening. This allows the boom
to open completely and prevents unintentional closing.
If automatic closing is disabled (
noeuvre
Condominium function: the barrier opens and closes after the set automatic closing time.
The automatic closing timer does NOT restart if a new step mode command is received.
Step mode commands are ignored while the barrier is opening. This allows the boom to open completely
and prevents unintentional closing.
If automatic closing is disabled (
noeuvre
Open-close-open-close.
Open-close-stop-open.
Pre-manoeuvre flashing warning
Disabled. The flashing light is activated during opening and closing manoeuvres.
Flashing warning signal for 1 to 10 seconds prior to every manoeuvre.
5 second flashing warning signal prior to closing manoeuvre.
).
), the condominium function automatically attempts a closing ma-
.
), the condominium function automatically attempts a closing ma-
.
PARAMETER
=
,
or
.
67