6 Putting into operation
1
separate
couple
LW5 LW5
4
2
14
12
12
14
5 3
1
1
Flange P
Y1 5/2-way valve
Z1 cylinder
Fig. 7
Pneumatic plan for dual action cylinder
EN - 12
2
lock
unlock
Z1
Z2
LW4
LW4
LW4
Y1
4
2
14
12
14
5 3
1
2
Tool rest 1
Y2 5/2-way valve
Z2+Z3 cylinders with return spring
S1 Proximity switch
BN
BK
BU
S1
Z2
Z3
LW4
LW4
LW4
Y1
12
14
3
WWS-CAT
3
lock
unlock
BN
BU
S1
Z3
LW4
LW4
LW4
LW4
4
2
14
12
Y1
12
5 3
1
Tool rest 2
Y2 5/2-way valve
Z2+Z3 cylinders with return spring
S1 Proximity switch
BK