SICK L4000 Instrucciones De Operación página 102

Ocultar thumbs Ver también para L4000:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 229
en
Chapter 9
102
 SICK AG • Industrial Safety Systems • Germany • All rights reserved
Technical data
9 )
Test pulse data
Test pulse width
Test pulse rate
Permissible line
resistance between
10 )
device and load
External device monitoring
(EDM) input
Permissible dropout
time (contactors)
Permissible pick-up time
(contactors)
Control switch input (reset
button)
Operation time control
switch input
Shock resistance
Rigidity
Housing fastening
Weight
9)
When active, the outputs are tested cyclically (brief LOW). When selecting the downstream controllers, make
sure that the test pulses do not result in deactivation when using the above parameters.
10)
Make sure to limit the individual cable resistance to the downstream controller to this value to ensure that a
cross-circuit between the outputs is safely detected. (Also note EN 60204 Electrical Machine Equipment,
Part 1: General Requirements.)
Operating Instructions
minimum
typical
200 λs
250 λs
2
/s
2.5
/s
1
1
350 ms
420 ms
50 ms
10 g 16 ms (IEC 60068-2-27)
5 g, 10 Hz ... 55 Hz (IEC 60068-2-6)
Snap fastening on 35 mm mounting rail
(DIN EN 50022)
160 g
8010009/YTA2/2016-05-02
L4000 system
maximum
450 λs
3
/s
1
10 ς
Subject to change without notice

Publicidad

Tabla de contenido
loading

Tabla de contenido