Chapter 5
WARNING
84
 SICK AG • Industrial Safety Systems • Germany • All rights reserved
Electrical installation
Prevent the formation of a potential difference between the load
and the protective device!
= If you connect loads that are not reverse-polarity protected to the
OSSDs or the safety outputs, you must connect the 0 V connections
of these loads and those of the corresponding protective device
individually and directly to the same 0 V terminal strip. This is the
only way to ensure that, in the event of a defect, there can be no
potential difference between the 0 V connections of the loads and
those of the corresponding protective device.