Fig. 20: L4000 (M30)
alignment aid adapter for
AR60
92
 SICK AG • Industrial Safety Systems • Germany • All rights reserved
Commissioning
How to align the sender and receiver using the laser alignment aid
AR60:
With large scanning ranges or on the usage of deflector mirrors, the
laser alignment aid AR60 significantly simplifies alignment.
= Screw the adapter onto the AR60.
= Mount the AR60 in front of the sender (screw on)
= Switch on AR60
= Attach a piece of white cardboard or cardboard with Scotchlite
(reflective tape) to the receiver (in this way the beam array is easier
to see)
= Align sender such that the laser beam array is incident on the
middle of the receiver optics
= Fix sender in this position
= Switch off AR60
= Remove AR60
= Switch on sensors