Operating Instructions
L4000 system
Tab. 12: Technical data,
L4000 sender/receiver
8010009/YTA2/2016-05-02
Subject to change without notice
Technical data
9.3
Data sheet, L4000 sender/receiver
Supply voltage
Power consumption
Electrical protection class III
Type
Safety Integrity Level
16)
SIL claim limit
Category
16)
Performance Level
PFHd (mean probability
of a dangerous failure
per hour)
T
(mission time)
M
Wavelength
Aperture angle/
receiving angle
Diameter (optics)
Distance sender-receiver 0 m
Ambient operating
temperature
Humidity (non-
condensing)
Storage temperature
Housing material
Optics
Enclosure rating
Response time
14)
For continuous sending (that is alignment, PIN 4 of the sender not connected)
15)
Only in conjunction with safety evaluation device UE401.
16)
For detailed information on the exact design of your machine/system, please contact your local SICK
representative.
SICK AG • Industrial Safety Systems • Germany • All rights reserved
minimum
19.2 V DC
24 V DC
Type 4 (IEC 61496-1)
16)
SIL3 (IEC 61 508)
SILCL3 (EN 62 061)
Category 4 (EN ISO 13 849-1)
PL e (EN ISO 13 849-1)
–10
2.9 × 10
20 years (EN ISO 13 849)
660 nm (red)
26 mm
–20 ↓C
15 %
–25 ↓C
Nickel plated brass
Glass
IP 67
LOW —=
HIGH: 0.4 ms
HIGH —=
LOW: 0.6 ms
Chapter 9
typical
maximum
28.8 V DC
14)
60 mA
(Sender)
30 mA
(receiver)
15)
°2.5↓
60 m
+55 ↓C
95 %
+75 ↓C
en