Tab. 5: Terminal Assignment Ue401 - SICK L4000 Instrucciones De Operación

Ocultar thumbs Ver también para L4000:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 229
en
Chapter 5
Tab. 5: Terminal
assignment UE401
Fig. 16: Example
connection of
L400/L4000 sensors in
cascade
86
 SICK AG • Industrial Safety Systems • Germany • All rights reserved
Electrical installation
Pin
Description
1
DC 24 V
2
GND
3
EDM input
4
OSSD 1
5
Receiver, sensor 1
6
Receiver, sensor 2
7
Receiver, sensor 3
8
Receiver, sensor 4
9
Deactivate restart interlock
10
Deactivate EDM
11
Reset button input
Restart interlock
12
OSSD 2
13
Sender, sensor 1
14
Sender, sensor 2
15
Sender, sensor 3
16
Sender, sensor 4
Connect the sensors to the safety evaluation device UE401 always
from left to right, starting from pin 5 and 13 in Fig. 15. Unused sensor
contacts must be connected with a jumper between the related
sender/receiver pin (starting with pin 8 and 16).
Unscreened cables can be used, see ordering information.
Operating Instructions
L4000 system
DC 24 V
DC 0 V
8010009/YTA2/2016-05-02
Subject to change without notice

Publicidad

Tabla de contenido
loading

Tabla de contenido