6.2
Electrical connections
DESCRIPTION
Mains power supply 230 V~ ±10% 50 Hz connection.
(H70/104AC-105AC/115V/BOX 115 V~ ± 10% 60Hz).
L N
For H70/104AC: ROGER MOTOR connection.
AP-CM-CH
N.B.
H70/105AC ONLY. The gate open stop limit switch may be connected to terminals AP-CM and
the gate closed stop limit switch may be connected to terminals CH-CM.
M
7
Commands and Accessories
and
.
N.B: limit switches not used with H70/105AC board must be disabled by
parameter
.
N.A. (Normally Open).
N.C. (Normally Closed).
CONTACT
7(COR)
7(COR)
9
10(LAM)
11(24V~)
13(COM)
12(SC)
13(COM)
12(SC)
13(COM)
DESCRIPTION
8
Connection for external power supply for courtesy light
8
Connection for external power supply for electric lock (potential free contact) 12 V~ max 15VA
3-5).
Power feed for external devices 6 W.
Connection for gate open indicator lamp 24 V
The function of the indicator lamp is determined by parameter
Photocell test connection
feed for the photocell transmitters (TX) may be connected to this.
Set the parameter
to enable the test function.
the contact changes state correctly.
H70/104AC only).
(potential free contact)
.
.