Enabled. The open (AP) or close (CH) button must be pressed continuously to operate the gate. The gate
stops when the button is released.
Gate open indicator / photocell test function
open.
Set
if the output SC
Set motor deceleration space (%)
N.B.:
parameter.
From 1% to 30% of the total gate travel.
Gate fully open/closed position control setting
The value selected must ensure that the gate is opened/closed correctly when it reaches the respective
mechanical stop.
Warning! Excessively low values cause the gate to reverse when it reaches the gate open/closed stop.
N.B.: parameter visible only with encoder enabled (
led (
or
Motor revolutions.
Partial opening adjustment (%)
N.B.
From 1% to 99% of total gate travel.
Setting additional time after direction inversion, with no encoder
N.B.: parameter visible only if encoder is disabled
the gate reverses for the elapsed manoeuvre time plus an additional time to allow the manoeuvre to be
completed.
3 s.
6 s. Recommended setting for installations with hydraulic motors.
Setting automatic closing time
the gate closes automatically. The timer count restarts if a photocell is triggered.
Pause time settable from 00 to 90 s.
Pause time settable from 2 to 9 min.
Set manoeuvre time
N.B.: parameter visible only if encoder is disabled
Warning!
Manoeuvre time settable from 00 to 99 s.
Enable double manoeuvre time
Enabling this parameter is recommended for installations with particularly long operating times.
N.B.: parameter visible only if encoder is disabled
Disabled.
Enabled.