Condominium function for partial open command (PED)
Disabled. The gate opens partially in step mode: open-stop-close-stop-open...
Enabled. Partial commands are ignored during gate opening.
Enabling operator present function.
Disabled.
Enabled. The open (AP) or close (CH) button must be pressed continuously to operate the gate. The gate stops
when the button is released.
Gate open indicator / photocell test function and "battery saving"
The indicator is off when the gate is closed, and steadily lit during manoeuvres and when the gate is open.
The indicator ashes slowly during opening manoeuvres, and is lit steadily when the gate is completely open. It
ashes quickly during closing manoeuvres.
If the gate is stopped in an intermediate position, the lamp extinguishes twice every 15 seconds.
Set
if the output SC is used for the photocell test. See g. 7-8.
Set to
if the output SC is used for the "battery saving" function. See g. 9-10.
When the gate is completely open or closed, the controller unit deactivates any accessories connected to terminal
SC to reduce battery consumption.
Set to
if the output SC is used for the "battery saving" function and photocell test function. See g. 9-10.
Setting deceleration during opening and closing
See chapters 14 and 15
01= the gate decelerates near the limit switch ... 05= the gate decelerates long before the limit switch.
Setting gate open limit switch constant speed approach distance
N.B.: the manoeuvre speed is set with parameter
limit switch at constant speed.
Setting gate closed limit switch constant speed approach distance
N.B.: the manoeuvre speed is set with parameter
limit switch at constant speed.
01= last 3 cm; 02= last 6 cm; ... 40= last 120 cm.
Approximate example: 100 cm distance = value
Partial opening adjustment (%)
N.B.: This parameter is set to 50% (half of total gate travel) by default.
From 10% to 99% of total gate travel.
COR output operating mode
STANDARD operation managed by parameter
Closed contact if the release handle is correctly closed (with the key turned to closed position).
Open contact due to a fault: Motor released and/or key turned to open position.
Contact closed if the motor is powered by the mains or charged battery.
Open contact due to a fault: Motor powered by low battery (voltage level set by par.
control unit no longer accept commands).
Closed contact if none of the fault related situations 1 and 2 occurs.
Open contact if at least one of the fault related situations 1 and 2 occurs
Closed contact if the gate is not completely open.
Open contact if the gate is completely open.
Closed contact if the gate is not completely closed.
Open contact if the gate is completely closed.
Setting automatic closing time
The timer starts from the gate open state and continues for the set time. Once the set time is reached, the gate
closes automatically. The timer count restarts if a photocell is triggered.
Pause time settable from 00 to 90 s.
Pause time settable from 2 to 9 min.
. After decelerating, the gate completes the distance to the
. After decelerating, the gate completes the distance to the
.
) or with error alert
(the
69